ADJUSTMENTS
WARNING : BEFORE SERVICING THIS CHASSIS, READ THE
PICTURE TUBE COMPONENTS ADJUSTMENT
SPECIFIC INFORMATIONS GENERAL
DESCRIPTION OF NECK COMPONENTS
21
1Deflection yoke and convergence yoke
The position on the neck is required most front (CRT funnel side) and the screw is fastened after rotating yoke adjusting picture tilt.
2Centering magnet
After adjusting picture tilt, picture position is finally fixed by this magnet.
In order to get maximum margin of user conver- gence control for center of screen, this magnet have to be used for center convergence adjust- ment.
PREPARATION
Operate the receiver for at least 5 minutes.
R, G, B FOCUS ADJUSTMENT
1.Before adjusting the R, G, B FOCUS, remove the 4 screws of Lens Assembly which is fixed on the CRT Assembly. (See page 4.)
Then turn around the Lens Assembly by 180˚ to adjust the fastening screw (Fig. a) and fasten the 4 screws to secure Lens Assembly.
2.Select the adjustment mode. (See page 9.)
3.Press “7” button to display the
4.Press “0” and “RTN” buttons to make the picture a sin- gle Red color.
100 button ............... to erase Red color
0 button ............... to erase Green color RTN button ............... to erase Blue color
5.Loosen the fasten screw and adjust Red lense focus to best focusing point of picture center. Then fasten the screw. (See Fig. a.)
Fig. a
6.Adjust FOCUS VR “R” of FOCUS PACK to find best focusing point of picture center.
7.Repeat steps 3 to 5 for Green and Blue colors.
– 6 –
TILT ADJUSTMENT
Rotate R, G, B deflection yoke so that picture becomes horizon, then fasten screw.
CENTERING ADJUSTMENT
1.Stretch a thread between two center slots of screen edge (top and bottom, left and right).
2.Select the adjustment mode.
3.Press TV/VIDEO button on the Remote Control to dis- play the white
4.Perform VCEN adjustment. (See page 11.)
5.Adjust G centering magnet so that the
6.Perform HEIGHT adjustment . (See page 12.)
7.Perform VERT. LINEARITY adjustment.
8.Perform WIDTH adjustment. (See page 12.)
9.Check whole quality of green line.
10.Adjust R, B centering magnet so that the