– 17 –
GENERAL ADJUSTMENTSSPECIFIC INFORMATIONS
SETTING & ADJUSTING DATA
43", 50", 55", 61"
HIGH VOLTAGE AT ZERO BEAM: (A) 31.3 kV
MAX HIGH VOLTAGE: (B) 32.4 kV
Table-1
CHAPTER 2 SPECIFIC INFORMATIONS
SAFETY INSTRUCTIONS
SERVICE MODE
ADJUSTING ITEMS AND DATA IN THE SERVICE MODE:
Item Name of adjustment
R CUTOFF
G CUTOFF
B CUTOFF
G DRIVE
B DRIVE
SUB CONT MAX
SUB-BRIGHT
SUB-COLOR
SUB-TINT
SUB COLOR
SUB-CONTRAST
HORIZ. POSITION
VERT. POSITION
HEIGHT
V-LINEARITY
V-S CORRECTION
PICTURE WIDTH
V-SHIFT
RCUT
GCUT
BCUT
GDRV
BDRV
CNTX
BRTC
COLC
TNTC
SCOL
SCNT
HPOS
VPOS
HIT
LIN
VSC
WID
VPS
Preset Date
40H
40H
40H
40H
40H
7FH
80H
50H
44H
05H
10H
19H
00H
64H
12H
10H
28H
18H
23H
Table-2
CIRCUIT CHECKS
Table-3
FBT DETECTION VOLTAGE (C) 24.5V
Item Name of adjustment Preset Date
VCP
PARA
CNR
TRAP
HCP
VFC
PHUE
PCNT
PCOL
RGBB
PROF
PBOF
PGOF
STRH
STRP
VLD
VCEN
TVOP
V-COMPENSATE
E-W PARABOLA (DPC)
E-W CORNER
TRAPEZIUM
H-COMPENSATE
V-F CORRECT
PIP TINT
PIP CONT
PIP COLOR
RGB BRIGHT
PIP R OFFSET
PIP B OFFSET
PIP YG OFFSET
START H
START PTN
VLD
V POSITION
TV OPTION
0AH
29H
08H
10H
00H
00H
00H
00H
0FH
54H
00H
00H
00H
67H
8AH
41H
81H
00H