GENERAL ADJUSTMENTS

REPLACEMENT OF THE CRT

Service parts are provided for each R, G and B.

The contents of the parts are as follows.

 

R

G

B

 

 

 

 

50A50

23796001

23005397

23796003

50A60

23005114

23005115

HITACHI

23005242

55A60

CRT

23005249

23796486

61A60

 

 

 

 

REPLACEMENT OF HIGH VOLTAGE CABLE

SPECIFIC INFORMATIONS

ANODE LEAD

RUBBER BOOT

LEAD HOLDER

Fig. a

Z450 TPA5007

1.When replacing Anode Lead or Anode Cap with new one, remove Lead Holder from old lead as shown in figure below, and put it on new lead. Do not throw away Lead Holder.

NOTE : THE LEAD HOLDER IS ATTACHED TO TPA5007 (Z450), BUT IS NOT ATTACHED TO ANODE LEAD AND ANODE CAP. RUBBER BOOT IS ATTACHED TO ANODE LEAD AND ANODE CAP.

2. Detaching Lead Holder

OLD

RUBBER BOOT ANODE LEAD or

ANODE CAP

LOCK LEAD HOLDER Cut here rubber boot and lead together to detach Lead Holder.

Fig. b

– 8 –

Page 8
Image 8
Toshiba 50A60, 50A50 55A60 service manual Replacement of the CRT, Replacement of High Voltage Cable