– 8 –
GENERAL ADJUSTMENTSSPECIFIC INFORMATIONS
REPLACEMENT OF THE CRT
Service parts are provided for each R, G and B.
The contents of the parts are as follows.
RGB
50A50 23796001 23005397 23796003
50A60 23005114 23005115
55A60 23005242 ↑↑
61A60 23005249 23796486
REPLACEMENT OF HIGH VOLTAGE CABLE
ANODE LEAD
RUBBER BOOT
LEAD HOLDER
Z450 TPA5007
Fig. a
1. When replacing Anode Lead or Anode Cap with new
one, remove Lead Holder from old lead as shown in
figure below, and put it on new lead. Do not throw away
Lead Holder.
NOTE: THE LEAD HOLDER IS ATTACHED TO
TPA5007 (Z450), BUT IS NOT A TT A CHED TO
ANODE LEAD AND ANODE CAP. RUBBER
BOOT IS ATTACHED TO ANODE LEAD AND
ANODE CAP.
2. Detaching Lead Holder
RUBBER BOOT OLD
ANODE LEAD
or
ANODE CAP
LOCK LEAD HOLDER Cut here rubber boot
and lead together to
detach Lead Holder.
Fig. b
HITACHI
CRT