5. MAINTENANCE

ENGLISH VERSION EO1-33028

5.1 Cleaning

5. MAINTENANCE

WARNING!

Be sure to disconnect the Power Cord before performing maintenance. Failure to do this may

cause an electric shock. To avoid injury, be careful not to pinch or jam your fingers while opening or

closing the cover and Print Head Block.

The Print Head may become hot. Do not touch the Print Head.

Do not pour water directly onto the printer.

This chapter describes how to perform normal maintenance.

To maintain the printer performance and quality print, please clean the printer regularly, or whenever media or ribbon is replaced.

5.1 Cleaning

5.1.1Print Head/Platen/ Sensors

CAUTION!

Do not allow any hard objects to touch the print head or platen, as this may cause damage to them.

Do not use any volatile solvent including thinner and benzene, as this may cause discoloration to the cover, print failure, or breakdown of the printer.

Do not touch the print head element with bare hands, as static may damage the print head.

Be sure to use the print head cleaner enclosed with this printer. Failure to do this may shorten the print head life.

NOTE:

Please purchase the Print Head Cleaner from the authorised TOSHIBA TEC service representative.

The following sections describe periodic cleaning of the unit.

1.Turn off the printer. Open the Top Cover.

2.Press the Head Block Release Lever to release the Print Head Block.

3.Raise the Print Head Block and remove the ribbon.

4.Clean the Print Head Element with the supplied Print Head Cleaner.

Print Head Cleaner

Print Head Element

(P/No.: 24089500013)

 

Print Head

5.Hold the Sensor Lift Tab and lift the Upper Sensor Ass’y.

6.Wipe the Feed Gap Sensor and Black Mark Sensor with a dry soft cloth.

7.Wipe the Platen with a soft cloth slightly moistened with ethyl alcohol.

Sensor Lift Tab

Platen

Feed Gap Sensor and

Black Mark Sensor

E5- 1

Page 35
Image 35
Toshiba B-852-TS12-QP owner manual Maintenance, Cleaning, Print Head/Platen/ Sensors