4 Replacement Procedures 4.31 LCD unit/FL inverter
4
4.31 LCD unit/FL inverter
CAUTION: When replacing a LCD, it is required that SVP parameter is set. Update with
the latest EC/KBC as described in Appendix H “EC/KBC Rewrite
Procedures”.
Removing the LCD unit/FL inverter
The following describes the procedure for removing the LCD unit and FL inverter (See
Figure 4-49 to 4-54).
1. Remove the hinge cap from the slot while releasing latches.
Hinge cap
Figure 4-49 Removing the hinge cap
4-70 [CONFIDENTIAL] QOSMIO F30 Maintenance Manual (960-555)