Toshiba GD-1221, GD-1220 service manual FCF format of each binary signal, Binary signal Format

Models: GD-1220 GD-1221

1 82
Download 82 pages 10.87 Kb
Page 44
Image 44

-FCF format of each binary signal

Binary signal

 

 

 

 

Format

 

 

 

 

 

 

 

 

 

 

 

 

b1

b2

b3

b4

 

b5

b6

b7

b8

 

 

NSF

0

0

0

0

 

0

1

0

0

 

 

 

 

 

 

 

 

 

 

NSC

1

0

0

0

 

0

1

0

0

 

 

 

 

 

 

 

 

 

 

NSS

x

1

0

0

 

0

1

0

0

 

 

 

 

 

 

 

 

 

 

CSI

0

0

0

0

 

0

0

1

0

 

 

 

 

 

 

 

 

 

 

CIG

1

0

0

0

 

0

0

1

0

 

 

 

 

 

 

 

 

 

 

TSI

x

1

0

0

 

0

0

1

0

 

 

 

 

 

 

 

 

 

 

DIS

0

0

0

0

 

0

0

0

1

 

 

 

 

 

 

 

 

 

 

DTC

1

0

0

0

 

0

0

0

1

 

 

 

 

 

 

 

 

 

 

DCS

x

1

0

0

 

0

0

0

1

 

 

 

 

 

 

 

 

 

 

SUB

x

1

0

0

 

0

0

1

1

 

 

 

 

 

 

 

 

 

 

SEP

1

0

0

0

 

0

1

0

1

 

 

 

 

 

 

 

 

 

 

PWD(Rx)

1

0

0

0

 

0

0

1

1

 

 

 

 

 

 

 

 

 

 

PWD(Tx)

x

1

0

0

 

0

1

0

1

 

 

 

 

 

 

 

 

 

 

CFR

x

0

1

0

 

0

0

0

1

 

 

 

 

 

 

 

 

 

 

FTT

x

0

1

0

 

0

0

1

0

 

 

 

 

 

 

 

 

 

 

EOM

x

1

1

1

 

0

0

0

1

 

 

 

 

 

 

 

 

 

 

MPS

x

1

1

1

 

0

0

1

0

 

 

 

 

 

 

 

 

 

 

EOP

x

1

1

1

 

0

1

0

0

 

 

 

 

 

 

 

 

 

 

MCF

x

0

1

1

 

0

0

0

1

 

 

 

 

 

 

 

 

 

 

RTN

x

0

1

1

 

0

0

1

0

 

 

 

 

 

 

 

 

 

 

PIP

x

0

1

1

 

0

1

0

1

 

 

 

 

 

 

 

 

 

 

PIN

x

0

1

1

 

0

1

0

0

 

 

 

 

 

 

 

 

 

 

PRI-EOM

x

1

1

1

 

1

0

0

1

 

 

 

 

 

 

 

 

 

 

PRI-MPS

x

1

1

1

 

1

0

1

0

 

 

 

 

 

 

 

 

 

 

PRI-EOP

x

1

1

1

 

1

1

0

0

 

 

 

 

 

 

 

 

 

 

DCN

x

1

0

1

 

1

1

1

1

 

 

 

 

 

 

 

 

 

 

RR

x

1

1

1

 

0

1

1

0

 

 

 

 

 

 

 

 

 

 

RNR

x

0

1

1

 

0

1

1

1

 

 

 

 

 

 

 

 

 

 

PPR

x

0

1

1

 

1

1

0

1

 

 

 

 

 

 

 

 

 

 

PPS

x

1

1

1

 

1

1

0

1

 

 

 

 

 

 

 

 

 

 

CTC

x

1

0

0

 

1

0

0

0

 

 

 

 

 

 

 

 

 

 

CTR

x

0

1

0

 

0

0

1

1

 

 

 

 

 

 

 

 

 

 

EOR

x

1

1

1

 

0

0

1

1

 

 

 

 

 

 

 

 

 

 

ERR

x

0

1

1

 

1

0

0

0

 

 

 

 

 

 

 

 

 

 

RTP

x

0

1

1

 

0

0

1

1

 

 

 

 

 

 

 

 

 

 

CRP

x

1

0

1

 

1

1

0

0

 

 

 

 

 

 

 

 

 

 

-X = 1 for the station which received DIS.

-X = 0 for the station which received a response signal to DIS.

GD-1220/1221

© 2006 - 2008 TOSHIBA TEC CORPORATION All rights reserved

DIALING/COMMUNICATION CONTROL

 

3 - 10

Page 44
Image 44
Toshiba GD-1221, GD-1220 service manual FCF format of each binary signal, Binary signal Format