The relation between the signals and sound volume is as follows.

Sound volume

VOLSEL2

VOLSEL1

VOLSEL0

 

 

 

 

Max. (7)

LOW

LOW

LOW

 

 

 

 

(6)

LOW

LOW

HIGH

 

 

 

 

(5)

LOW

HIGH

LOW

 

 

 

 

(4)

LOW

HIGH

HIGH

 

 

 

 

(3)

HIGH

LOW

LOW

 

 

 

 

(2)

HIGH

LOW

HIGH

 

 

 

 

Min. (1)

HIGH

HIGH

LOW

 

 

 

 

Silent (0)

HIGH

HIGH

HIGH

 

 

 

 

The monitoring signal whose volume is controlled by IC9 [IC2] is amplified by the OP amplifier (IC10 [IC1]), then output to the speaker.

Signal Name

Type

Active

Description

Destination

 

 

 

 

 

SP-SEL

O

H

Line/Tone Selection Signal

IC3

 

 

 

 

 

MON

O

H

Ring/Tone Selection Signal

IC3

 

 

 

 

 

VOLSEL0-2

O

H

Speaker Volume Control Signals 0-2

IC9 [IC2]

 

 

 

 

 

*Values in [ ] are for GD-1250/1270 in case that the descriptions vary between GD-1210 and GD- 1250/1270.

4

© 2006 - 2011 TOSHIBA TEC CORPORATION All rights reserved

GD-1210/1250/1270/1160/1260

 

ELECTRICAL CIRCUITS

4 - 15

08/04

Page 83
Image 83
Toshiba GD-1160, GD-1260, GD-1250, GD-1270, GD-1210 Relation between the signals and sound volume is as follows, Sound volume