- 19 -
7.3 SENS (sensitivity setting)

The sensitivity of this unit can be se to AUTO and MANUAL.

Place the cursor “on MODE, press the [DATA UP] or [DATA DOWN] button, and select

the desired mode from AUTO and MANUAL.

AUTO:Automatically control the exposure time to get the set level.

MANUAL: The camera operates with the fixed sensitivity. Lens automatic iris control

function works except when long term exposure is set.

7.3.1 When Changing Setting of AUTO SENS Mode

Up/down movement
by MENU UP/DOWN
Set by DATA
UP/DOWN
-- 1 SENS -- <FILE A>
<SENS MODE=AUTO>
MODE AUTO
FLICKER OFF
CMG MAX CMG5
AGC MAX OFF
SS LONG MAX OFF
LEVEL 0
PEAK/AVE AVERAGE
AREA PRESET A
SENS mode AUTO, MANUAL
Display of SCENE file
Flicker correction ON, OFF
Setting of maximum value of OFF, CMG1, CMG2, , CMG10
AUTO electronic multiplication
Setting of maximum value of OFF, 1dB, 2dB, , 18dB
AUTO circuit gain
Setting of maximum value of OFF, 2FLD, 4FLD, , 256FLD
AUTO long term exposure
Adjustment of AUTO SENS -100, -99, , 0, 1, , 100
level
Brightness detection, average AVERAGE, PEAK
value, peak mode selection
Selection of brightness PRESET A, PRESET B,
detection area PRESET C, PRESET D,
PRESET E, PRESET F,
PRESET G