7.3.3 When Changing Settings of MANUAL mode (Synchro. Scan mode)

Up/down movement

 

Set by DATA

by MENU UP/DOWN

 

UP/DOWN

 

 

 

-- 1 SENS --

<FILE A>

MODE MANUAL

 

SHUTTER SS

 

SYNCRO SCAN

30FLD

CMG

OFF

GAIN

OFF

LEVEL

0

PEAK/AVE

AVERAGE

AREA

PRESET A

Display of SCENE file

 

SENS mode

AUTO, MANUAL

Electronic shutter mode

MANUAL, SS

Synchro. Scan shutter speed

9/262.5H, 10/262.5H, , 255/262.5H,

 

OFF, 2FLD, 4FLD, 6FLD, , 256FLD

Electronic multiplication gain OFF, CMG1, CMG2, , CMG10

Circuit gain

OFF, 1dB, 2dB, , 18dB

<SENS MODE=MANUAL, SHUTTER MODE=SS>

(1)Changing the setting of Synchro. Scan shutter speed

q Using the [MENU UP] or [MENU DOWN] button, place “” on SYNCHRO SCAN. w Using the [DATA UP] or [DATA DOWN] button, select the shutter speed.

[DATA UP]

9/262.5H 255/262.5H OFF 2FLD 256FLD

[DATA DOWN] Long term exposure

*Electronic multiplication gain and circuit gain can be set as in the case of MANUAL electronic shutter mode. (Refer to 7.3.2 (2)/(3))

Note

When setting the MANUAL long term exposure, the automatic iris cannot used.