(1. 3) Changing the setting in E.TRG mode

The E.TRG has five modes; 1P SNR, 1P SR, PW SNR, PW SR, RR.

First move the "→" to MODE and select E. TRG, then move the "→" to E.TRG and select the desired E.TRG mode.

(1. 3. 1) Changing the setting in 1P SNR mode

Move up down by pushing

MENU UP, DOWN

Select the desired value by pushing

DATA UP, DOWN

-- SHUTTER --

 

MODE

E.TRG

E.TRG

1P SNR

TRG.P

 

EXP.

16ms

PART

OFF

<MODE = E.TRG E.TRG = 1P SNR>

Sutter mode MANU, SS, E.TRG

E.TRG mode

1P SNR, 1P SR, PW SNR, PW SR, RR

• Input trigger pulse setting at 1P SNR and 1P SR

Input trigger pulse : positive polarity Input trigger pulse : negative polarity

• Exposure time setting at 1P SNR and 1P SR 0.01 ms0.02 ms0.4 ms1 ms16 ms

0.01 ms

0.02 ms

0.1 ms

1 ms

step

step

step

step

Partial scanning switch OFF/90fps/115fps/120fps/160fps/180fps/240fps/ E90fps/E115fps/E120fps/E160fps/E180fps/E240fps

(a) Changing the polarity of inputting trigger pulse setting

1Move the "→" to TRG.P by pushing [MENU UP], [MENU DOWN] buttons.

2Select either , by pushing [DATA UP], [DATA DOWN] buttons.

(b) Changing 1P SNR exposure time setting

1Move the "→" to EXP. by pushing [MENU UP], [MENU DOWN] buttons.

2Select the exposure time by pushing [DATA UP], [DATA DOWN] buttons.

(c) Changing the partial scanning setting

1Move the "→" to PART by pushing [MENU UP], [MENU DOWN] buttons.

2Select the mode by pushing [DATA UP], [DATA DOWN] buttons.

16

Page 16
Image 16
Toshiba IK-TF5U instruction manual Changing the setting in E.TRG mode, Changing the setting in 1P SNR mode