(1. 3) Changing the setting in E.TRG mode
The E.TRG has five modes; 1P SNR, 1P SR, PW SNR, PW SR, RR.
First move the "→" to MODE and select E. TRG, then move the "→" to E.TRG and select the desired E.TRG mode.
(1. 3. 1) Changing the setting in 1P SNR mode
Move up down by pushing
MENU UP, DOWN
Select the desired value by pushing
DATA UP, DOWN
| |
MODE | E.TRG |
E.TRG | 1P SNR |
TRG.P |
|
EXP. | 16ms |
PART | OFF |
<MODE = E.TRG E.TRG = 1P SNR>
•Sutter mode MANU, SS, E.TRG
•E.TRG mode
1P SNR, 1P SR, PW SNR, PW SR, RR
• Input trigger pulse setting at 1P SNR and 1P SR
Input trigger pulse : positive polarity Input trigger pulse : negative polarity
• Exposure time setting at 1P SNR and 1P SR 0.01 ms0.02 ms0.4 ms1 ms16 ms
0.01 ms | 0.02 ms | 0.1 ms | 1 ms |
step | step | step | step |
•Partial scanning switch OFF/90fps/115fps/120fps/160fps/180fps/240fps/ E90fps/E115fps/E120fps/E160fps/E180fps/E240fps
(a) Changing the polarity of inputting trigger pulse setting
1Move the "→" to TRG.P by pushing [MENU UP], [MENU DOWN] buttons.
2Select either , by pushing [DATA UP], [DATA DOWN] buttons.
(b) Changing 1P SNR exposure time setting
1Move the "→" to EXP. by pushing [MENU UP], [MENU DOWN] buttons.
2Select the exposure time by pushing [DATA UP], [DATA DOWN] buttons.
(c) Changing the partial scanning setting
1Move the "→" to PART by pushing [MENU UP], [MENU DOWN] buttons.
2Select the mode by pushing [DATA UP], [DATA DOWN] buttons.
16