Toshiba IK-TF5U Synchro. Scan Operation, Setting by the frame, Returning to factory settings

Models: IK-TF5U

1 36
Download 36 pages 26.36 Kb
Page 24
Image 24

( 7 ) Returning to factory settings

All the settings can be returned to the factory default status (preset status).

(1)If characters are displayed on the screen, press the [DISP] button to disable the character display.

(2)Push [MENU DOWN] and [DATA DOWN] buttons simultaneously for approx. 1 second.

(3)The preset operation starts. When the preset operation finishes, the character PRESET OK is displayed for approx. 1 second.

7. 3 Synchro. Scan Operation

The shutter speed can be set by the horizontal scanning period (1H) or by the frame.

( 1 ) Setting by 1H

1H/525H ~ 524H/525H stands for the setting by the 1H and the shutter speed can be set by the 1H (31.8 s). When operating Partial Scannig, the number’s listed below can be used for setting.

Partial scanning OFF

1H/525H ~ 524H/525H

90fps, E90fps

1H/348H ~ 347H/348H

115fps, E115fps

1H/272H ~ 271H/272H

120fps, E120fps

1H/262H ~ 261H/262H

160fps, E160fps

1H/197H ~ 196H/197H

180fps, E180fps

1H/175H ~ 174H/175H

240fps, E240fps

1H/131H ~ 130H/131H

( 2 ) Setting by the frame

2FRM to 512FRM stand for the setting (long period exposure) by the frame.

The video signal stored during the frame period set is output as 1 frame video image at a frame interval specified.

(Internal VD)

RGB data (video interval image)

FVAL

LVAL,

DAVL

n

n+1

(4FRM setting)

24

Page 24
Image 24
Toshiba IK-TF5U Synchro. Scan Operation, Setting by the frame, Returning to factory settings, Setting by 1H