LF410/LF600 LF410/LF602

Unit : mm

 

 

R(PT)½ Male Screw (Two places)

 

 

 

 

 

 

 

 

 

88

 

 

 

(126)

 

 

 

 

 

 

 

 

 

 

 

40

 

(35)

 

 

91

 

 

 

(L2)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Φ66

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

87

 

 

 

 

 

L1

Note1: Cable glands are not provided for LF414 of FM and CSA approved type.

Refer to the part Cable connection port at detector. Note2: 1 inch = 25.4mm

BS16, DIN PN16 and JIS 10K dimensions:

Meter size

L1

L2

D1

Weight

(mm)

(mm)

(mm)

(mm)

(kg)

25

80

168

66

approx. 3

Unit : mm

 

 

 

 

R(PT)½Male Screw (Two places)

 

 

 

 

 

 

 

 

 

 

 

88

 

 

 

 

 

(126)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

40

 

 

 

(35)

 

 

91

 

(L2)

ΦD1

L1

Note1: Cable glands are not provided for LF414 of FM and CSA approved type.

Refer to the part of Cable connection port at detector.

Note2: Eye bolts are provided at the top for flowmeters sized 200mm (8").

Note3: 1 inch = 25.4mm

ANSI class 150 and class 300 dimensions:

Meter size

L1

L2

D1

Weight

(inch)

(inch)

(inch)

(inch)

(lb)

1

3.15

6.61

2.60

approx. 7

Figure 7. Separate type detectors

LF410 and LF414

Meter size 25mm (1")

The dimension of L1 is changed when the material of grounding ring is chosen Pt-Ir or Ta

Meter size

 

L1

15mm (1/2”)

77mm

(3.03 inch)

25mm (1”)

95mm

(3.74 inch)

40mm (1 1/2”)

115mm (4.53 inch)

50mm (2”)

126mm (4.96 inch)

80mm (3”)

126mm (4.96 inch)

100mm (4”)

136mm (5.35 inch)

150mm (6”)

242mm (9.53 inch)

200mm (8”)

312mm

(12.28 inch)

BS16, DIN PN16 and JIS 10K dimensions:

Meter size

L1

L2

D1

Weight

(mm)

(mm)

(mm)

(mm)

(kg)

40

100

190

85

approx. 4

50

110

207

102

approx. 5

80

110*

232

127

approx. 6

100

120*

264

159

approx. 9

150

230

324

216

approx. 21

200

300

385

267

approx. 35

ANSI class 150 and class 300 dimensions:

Meter size

L1

L2

D1

Weight

(inch)

(inch)

(inch)

(inch)

(lbs)

1-1/2

3.94

7.48

3.35

approx. 9

2

4.33

8.15

4.02

approx. 11

3

4.33*

9.13

5.00

approx. 13

4

4.72*

10.39

6.26

approx. 20

6

9.06

12.76

8.50

approx. 47

8

11.81

15.16

10.51

approx. 78

*When Teflon PFA lining is selected, L1 in the table above becomes as follows:

L1: 115mm (4.53 inch) for meter size 80mm (3")

L1: 126mm (4.96 inch) for meter size 100mm (4")

Figure 8. Separate type detectors

LF410 and LF414

Meter size 40 (1 1/2") to 200mm (8")

7

Page 7
Image 7
Toshiba LF410/LF602, LF410/LF600 specifications Separate type detectors LF410 and LF414 Meter size 25mm