LF410/LF600 LF410/LF602

151

4 – Φ11

Attachment

 

74±0.3

LCD display

 

 

 

 

 

 

 

 

 

 

151

 

 

178

 

200

 

156

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(36)

IR Switch

赤外線スイッチ Cable ground

25

82

13

 

Unit : mm

 

 

 

 

Excitation cable ground

 

 

 

 

I/O cable ground

 

 

 

 

Ground地端子terminal

 

 

 

 

(M4)(M4)

 

 

 

 

取付金具

 

 

Signal cable ground

Power supply cable ground

 

 

 

 

電源ケーブルグランド

 

 

グランド

Blind封止栓screw

 

 

 

矢視A

 

Figure 9. Separate type converter LF602

External Connections

Combined type LF410/LF600 and LF414/LF600 flowmeters

I/O Cable (CVV-S)

Instrument Panel : Ordered separately

 

Ground terminal

 

 

Current output

Intermediate

(4~20mAdc) or

PROFIBUS

voltage (IV) wire,

Digital Output 1

2

5.5mm or more.

Signal common

 

To be grounded

for DI and DO

Digital Output 2

with 100Ω or less

ground resistance.

Digital Input

 

(20 to 30Vdc)

 

Grounded with

 

100Ω or less

 

ground resistance

 

Grounded with

 

100Ω or less

 

ground resistance

 

Power supply

Power Cable (CVV)

*1

Power Switch

 

(External double-pole power switch)

*1 Locate an external double-pole power switch on the power line near the flowmeter within easy reach of operation. Use the appropriate switch rating as shown below:

Switch rating: 250Vac, 6A or more

In rush current: 15A or more

Figure 10. Combined type LF410/LF600 and LF414/LF600

flowmeters Wiring Diagram

8

Page 8
Image 8
Toshiba LF410/LF602 specifications External Connections, Combined type LF410/LF600 and LF414/LF600 flowmeters