LF410/LF600 LF410/LF602

totalizer.

Fixed-value outputs — Outputs fixed-values for current and pulse outputs.

Zero adjustment — Executes zero adjustment (on-stream at zero flow rate).

Output signals

Current output:

4–20mAdc (load resistance 0 to 750Ω)

Note: The current output cannot be used with the PROFIBUS-PA ccommunication.

Digital outputs — One point (std.) and one more point is optionally available as follows.

Digital output DO1 (std.):

Output type: Transistor open collector

Number of outputs: One point

Output capacity: 30Vdc, 200mA maximum

Digital output DO2 (opt.):

Output type: Solidstate relay output (non polarity)

Number of outputs: One point

Output capacity: 150Vdc, 150mA maximum or 150 V ac (peak to peak), 100mA maximum

DO1 and DO2 functions — One of the following functions can be assigned to DO1 (std.) and/or DO2 (opt.)

Pulse output (available only for DO1,DO2) Pulse rate: 3.6 to 36,000,000 pulses/hr (DO1)

3.6 to 360,000 pulses/hr (DO2) (Over 3,600,000 pulses/hr, auto-setting)

Pulse width: 0.5 to 500ms (but less than half of the period for 100% flow rate)

Note: The same and simultaneous pulse is not available between DO1 and DO2.)

Multi-range selection outputs (Note 1)

High, High high, Low, and/or Low low alarm outputs (Note 2)

Empty pipe alarm output

Digital Output Active Status (DO1 and DO2) (Note 2)

Preset count output

Converter failure alarm output

Note 1: Two outputs (DO1 and DO2) are needed for 4-range switching and forward/reverse 2-range switching.

Note 2: Normal Open (default set) or Normal Close

is selected for alarm outputs when programming.

The Status when power failure is kept to Normal Open.

Communications output

HART(std.)

Digital signal is superimposed on 4–20mAdc current signal as follows:

Conforms to HART protocol Load resistance: 240 to 750Ω Load capacitance: 0.25µF maximum Load inductance: 4mH maximum

PROFIBUS (opt.) Protocol : PROFIBUS-PA Baurate : 31.25kbps Bus voltage : 9-30Vdc

Consumption electric current of bus:less than 16mA

Manufacture Ident-No. : 093BHEX

Standard Ident-No. : 9740HEX

Slave address : 0-126 (Default address is 126)

Profile : Profile Ver.3.01 for Process Control Devices

Function blocks : AI(Flow)×1 , Totalizer×1

LCD display: Full dot-matrix 128×128 dot LCD display (back-light provided)

The data on the LCD inside the converter can rotate to 90, 180, and 270 degrees by a software, without rotating the indicator itself. (Combined type only)

Parameter settings — Parameters can be set as follows:

IR Switches: Three key switches are provided to set configuration parameters.

Digital communication: The AF900 hand-held terminal or PROFIBUS is needed to set

parameters.

•Zero adjustment: Zero point adjustment can be started by pressing the switch in the converter.

Damping: 0.5 to 60 seconds (selectable in 1 second increments)

Zero and span calibration: Built-in calibration signal source allows converter unit check.

Conditions when power fails: The outputs and display will remain as follows when power fails. Parameter setting values are stored in non-volatile memory and the values will be restored when the power returns to normal condition.

Current output: 0mAdc

Digital output: OFF

LCD display: No display

PROFIBUS: No communication

Power supply: One of the following can be selected:

100 to 240Vac, 50/60Hz (std.) (allowable voltage 80 to 264Vac)

24Vdc (allowable voltage 18 to 36Vdc)

110Vdc (allowable voltage 90 to 130Vdc)

Surge protection: Arresters are installed in the power supply, and current signal output circuit.

Case: Aluminum alloy (equivalent of IP 67)

Coating: Acrylic resin-baked coating, pearl-gray colored

3

Page 3
Image 3
Toshiba LF410/LF602, LF410/LF600 Digital output DO1 std, Digital output DO2 opt, Communications output : HARTstd