Piping Precautions
(1)Design piping so that the flowmeter detector pipe is always filled with the fluid being measured,
whether the fluid is flowing or not.
(2)The detector has no adjustable piping mechanism. Install an adjustable short pipe where needed.
(3) The required straight pipe length should comply with the requirements as follows.
(4)Be sure to grounding the flowmeter according to below figure.
| ° | L≧5D | |
Upstream side | When using a 90 bent, Tee, diffuser, or fully opened valve | ||
When using other types of valves | L≧10D | ||
| |||
Downstream side | When no valve plate protrudes into the detector pipe | L≧0 | |
L:Required straight pipe length |
|
D:Meter size
Grounding of the Combined type and Separate type
Combined type | Separate type |
Grounding terminal
Grounding terminal
Grounding wire
Grounding wire
Grounding terminal
(100 ohm or less
ground resistance)
Gasket
(100 ohm or less | Gasket |
ground resistance) | (100 ohm or less |
| ground resistance) |