(3) Installation of ceiling panel

The angle change of the flap is possible while the power supply is turned on. (Do not move forcibly the flap with hands. It may break the flap.)

1.For tentative hanging, insert the tentative hanging metal (stainless) inside of the ceiling panel into the square hole of the indoor unit. (Fig. 2)

Square hole of indoor unit

Push to remove

(5) Installation of adjust corner cap/suction grille

Install the adjust corner cap/suction grille in the reverse procedure of installation to the indoor unit.

• For this ceiling panel, as shown in the following figure, the

direction of the suction grille can be changed on customer’s

Pin

The ceiling panel has directional ability against the indoor unit. Direct the mark of refrigerant pipe at the ceiling panel corner toward the pipe side.

Holding the ceiling panel, remove it while pushing the tentative hanging metal toward the outside.

2.Match the mounting hole of the panel with the screw hole of the indoor unit.

3.Using the attached screws with washer, tighten 4 positions at corners of the suction port until the panel is fitted closely to the main unit. (Fig. 3)

4. Check the panel is fitted closely to the ceiling.

In this time, check there is no clearance between the indoor unit

and the ceiling panel, and between the ceiling panel and the

Ceiling panel

ceiling surface. (Fig. 4)

 

Tentative hanging metal

(Fig. 2)

Corner of drain pipe

Square hole of indoor unit

Draining mark

demand when multiple indoor units are installed.

A.Installation of adjust corner cap

1.Hook the strap of the adjust corner cap surely to the pin on the ceiling panel.

2.Install the adjust corner cap to the ceiling panel, and fix it with the mounting screws. (accessory part)

B.Installation of suction grille

• To install the suction grille, follow to the reverse procedure of the

removal. This ceiling panel can be installed from anyone of 4

directions by turning the suction grille. Change the direction on

the customer’s demand or according to the direction matching of

Install the adjust corner cap horizontally to the ceiling surface so that 3 hooks of the adjust corner cap are set in holes of the ceiling panel. And then fix it with the mounting screws (accessory part).

Hook hole of ceiling panel

 

Indoor unit

No clearance

 

 

 

 

 

Screw

Mark of

(Fig. 4)

Ceiling surface

Ceiling panel

(Fig. 3) with washer

refrigerant pipe

Tentative hanging metal

CAUTIONS

 

the suction grille when multiple units are installed.

When installing the suction grille, be sure not to pinch the

 

flap motor wiring connector.

Be sure to attach a strap to prevent falling of the suction grille to

 

the ceiling panel.

(Fig. 8)

Hook of fall-preventive strap

66

Tighten the screws securely because • When there is a clearance between the

a trouble is caused as shown in the

ceiling surface and the ceiling panel

following figure if the screws are

even if the screws have been tightened,

incompletely tightened.

readjust height of the indoor unit.

Air leak

 

The height of the indoor unit can be adjusted from corner hole on the ceiling panel as the ceiling panel is installed if the adjustment does not affect the levelness of the indoor unit, drain pipe, etc.

3. Others

Air leak

 

 

from ceiling

 

 

Generation

Dewing/water

Adjust so that there is

of dust

leak

no clearance.

(Fig. 5)

(Fig. 6)

After adjustment, be sure to tighten the mounting nut of the indoor unit securely.

Positions of suction grille hooks at shipment from the factory

 

 

* Although the suction grille can be installed from any

Drain pipe side

position of 4 corners, these positions are recommended.

of indoor unit

It is unnecessary to remove the suction grille in

 

 

(maintenance for the electric parts box of the indoor unit. )

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A. Check after installation

 

Electric parts box

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

• Check again there is no clearance between the

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

of indoor unit

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Refrigerant pipe side of indoor unit

Wireless remote controller kit (sold separately)

(Fig. 9)

 

(4) Cabling of ceiling panel

1.

Open cover of the electric parts box.

2.

Connect the flap motor wiring connector out

 

of the ceiling panel to the connector 5P

Wiring explanation diagram

(For explanation, direction of the indoor unit is changed.)

Electric parts box cover

indoor unit and the ceiling panel, and between the ceiling panel and the ceiling surface.

*A clearance causes water leak or dewing.

Check the cables are connected surely.

*Incomplete connection causes a trouble such as the flap does not work.

(CN33: white) on P.C. board of the indoor unit.

Screws

Flap motor wiring connector

Connect the connector surely because

 

the flap does not work if the connector

 

is not connected.

3. Mount cover of the electric parts box in the

reverse procedure of opening of the cover.

Check whether the wiring connector is

 

pinched between the electric parts box

 

and the cover or not.

Check whether the wiring connector is

 

pinched between the indoor unit and the

 

ceiling panel or not.

(3 positions)

CN33

Clamper

As shown in the figure, pass the clamping material through inside of the slit. After connection, store the connector section in the electric parts box.

(Fig. 7)

B. For wireless remote controller

Direction-free in 360˚

• For details of installation, refer to the Installation Manual attached to the wireless remote controller kit (sold separately).

After confirmation of the above items, hand a set of this manual, manuals for the indoor unit, manual for products sold separately, etc. to the customer. For cleaning of the filter, be sure to ask the maintenance professional.

EH99708701-(1) (EN)

Page 69
Image 69
Toshiba RAV-SM1400UT-E Installation of adjust corner cap, Installation of suction grille, Check after installation

RAV-SM1400UT-E, RAV-SM1100UT-E specifications

Toshiba has consistently been recognized for its commitment to innovation and quality in the HVAC market, and the RAV-SM1100UT-E and RAV-SM1400UT-E models exemplify this dedication. These inverter air conditioners are designed to provide efficient cooling and heating solutions for diverse applications, ensuring comfort in both residential and commercial spaces.

One of the standout features of the RAV-SM1100UT-E and RAV-SM1400UT-E is their advanced inverter technology. This technology allows the units to adjust their cooling and heating capacities based on the real-time conditions, leading to significant energy savings compared to traditional fixed-speed systems. The inverter allows for smooth operation at varying speeds, reducing energy consumption while maintaining a consistent indoor climate.

Both models offer exceptional efficiency ratings. With a high energy efficiency ratio (EER) and seasonal energy efficiency ratio (SEER), these units are designed to operate sustainably while delivering powerful performance. The RAV-SM1100UT-E offers a cooling capacity of 11 kW, while the RAV-SM1400UT-E boasts a more robust 14 kW, making them suitable for a range of spaces from smaller offices to larger commercial properties.

Another significant characteristic is their quiet operation. Toshiba has engineered these units to minimize noise levels, ensuring a tranquil environment. This is particularly beneficial in settings like hotels, restaurants, and workplaces where noise can be disruptive.

The RAV-SM series is also equipped with intelligent control technology. This feature allows users to manage the system from anywhere using a smartphone app, providing convenience and flexibility. Integration with smart home systems further enhances usability, making it easy to program schedules and adjust settings remotely.

Additionally, both models employ a variety of robust filtration systems, ensuring that the circulated air is clean and healthy. With filters that capture dust, allergens, and other particles, these units contribute to improved indoor air quality.

Durability is another hallmark of Toshiba's design philosophy. These air conditioners are built with high-quality materials, ensuring long-lasting performance and reliability even in demanding environments. The RAV-SM models are also designed to work efficiently in low outdoor temperatures, extending their usefulness throughout the year.

In summary, the Toshiba RAV-SM1100UT-E and RAV-SM1400UT-E air conditioners represent a fusion of innovation, efficiency, and user-centric design. With their advanced inverter technology, energy efficiency, quiet operation, intelligent controls, and durable construction, they stand as ideal solutions for those seeking effective climate management in their spaces.