Toshiba RAV-SP180AT2-UL installation manual „Installation Location

Models: RAV-SP180AT2-UL

1 20
Download 20 pages 28.8 Kb
Page 9
Image 9
„Installation Location

Outdoor Unit

„Installation Location

– 8 – WARNING

Install the outdoor unit in a location that can support the weight of the outdoor unit.

Insufficient durability may cause the outdoor unit to fall, which may result in injury.

Installation Manual

When an outdoor unit is installed in a location that is always exposed to strong winds like a coast or on the high stories of a building, one of the following is recommended.

Install the unit so that its discharge faces the wall of the structure.

Keep a distance 19.7” (500 mm) or more between the unit and wall.

19.7" (500 mm)

Manual background CAUTION

Do not install the outdoor unit in a location that is subject to combustible gas leaks.

Accumulation of combustible gas around the outdoor unit may cause a fire.

Install the outdoor unit in a location that meets the following conditions.

A well-ventilated location free from obstacles near the air inlets and air outlet

A location that does not increase the operating noise or vibration of the outdoor unit

A location that does not produce any drainage problems from discharged water

Location with easy access to power.

Do not install the outdoor unit in the following location.

A location with a saline atmosphere (coastal area) or one that is full of sulfide gas (hot-spring area) (Special maintenance is required.)

A location subject to oil, vapor, oily smoke, or corrosive gases

A location in which organic solvent is used

A location where high-frequency equipment (including inverter equipment, private power generator, medical equipment, and communication equipment) is used (Installation in such a location may cause malfunction of the air conditioner, abnormal control or problems due to noise from such equipment.)

A location in which the discharged air of the outdoor unit blows against the window of a neighboring house

A location where the operating noise of the outdoor unit is transmitted

When the outdoor unit is installed in an elevated position, be sure to secure its feet.

A location in which drain water poses any problems.

Install the unit so that the discharge is at a right angle relative to the wind direction.

Strong wind

Strong wind

Use wind baffle. Produce those parts in the field.

When outside temperature conditions are 23 °F (-5 °C) or lower and unit is running in cooling mode.

<Example>

Wind baffle

Wind baffle

EN

– 8 –

8-EN

Page 9
Image 9
Toshiba RAV-SP180AT2-UL installation manual „Installation Location