3.3.2.Installation

(1)The mounting surface of the equipment must keep good flatness.

When mounting, care should be paid that an excessive force which may caused torsional distortion on the equipment does not apply to the equipment. The recommended surface flatness for the mounting surface should be less than 0.2 mm.

(2)Install the equipment with enough space as much as possible in all directions around the equipment. Care should be paid that the equipment does not touch with peripheral instruments even if vibration, mechanical shock, etc. are applied to the equipment.

For the maximum dimension of the equipment thickness (12.9 mm), it is recommended that a clearance more than 0.5 mm should be left the thickness direction.

For the clearance around the front bezel, it is recommended that the clearance more than 0.8 mm should be left in all directions.

(3)Care should be especially paid for the heat effect. Keep the air ventilation and isolate from heat of the environmental condition. Then, install the equipment where the environmental temperature at the bottom center of cabinet does not exceed 50 °C.

(4)Do not add the force beyond the indicated force on the top and bottom cover of the equipment. (The restricted force range for the top cover is shown in the Figure 2.) (For the bottom cover, the applied force should be less than 2N on whole area.)

129

 

 

 

2 N

 

 

 

 

 

1 N

 

 

 

R63

 

0.5 N

 

 

 

 

 

 

 

 

R59

 

 

 

 

 

 

 

 

37

 

 

R46

 

Do not add

24

 

 

 

 

 

 

 

 

the force

5.4

 

 

 

 

 

 

 

 

 

20

 

7

11

64

70

74

128

Figure 2 Restricted force range applied for the top cover

(5)The characteristics of EMC (Electro Magnetic Compatibility) are primarily influenced by the mounting method of this equipment. Attach this equipment by considering an appropriate method and structure.

8/28

SD-R6112 Rev.1.0

Page 13
Image 13
Toshiba SD-R6112 specifications R63 R59 R46 Do not add Force