11.Emergency Release

Execute following procedure only in the case of emergency (Drawer will not release and disc can not be removed although pressing Release Button).

(1)Turn the drive supplying power off.

(2)Insert solid bar (like paper clip) into Emergency Release hole and push as shown in Fig.24. Then Drawer will be released.

(3)After removed the disc, gently push Drawer to close.

 

15 mm

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

diameter 1.0 mm

 

 

 

 

Figurer 24 Emergency Release

12.Safety Standards/Agency Approvals

(1) Safety

EN60950

 

UL 1950

 

CAN/CSA-22.2 No.950

(2) Laser

FDA 21CFR (U.S.A./DHHS)

 

EN60825-1 (Europe/Canada)

(3) EMC

89/366/ECC (CE-Mark)

EN50081-1

: 1992 [Residental, commercial & light industry]

EN55022

: 1998 [Class B]

EN55024+A1

: 1998+2001 [Information Technology equipment-

 

Immunity characteristices Limits and

 

methods of masurement]

IEC61000-4-2+A1

: 1995+1998 [CD:4 kV, ID: 4 kV, AD:8 kV]

IEC61000-4-3+A1

: 1995+1998 [3 V/m, 80-1000 MHz, 1 kHz 80 %

 

AM ]

IEC61000-4-4

: 1995 [AC-line: 1 kV, I/F 0.5 kV

 

f: 5 kHz, Polarity: +/-]

IEC61000-4-5

: 1995 [AC-line: 2 kV/1 kV, Polarity: +/-]

IEC61000-4-6

: 1996 [3 V, 0.15-80 MHz, 80 % AM]

IEC61000-4-8

: 1993 [1 A/m, 50 Hz]

IEC61000-4-11

: 1994 [>95 % 0.5, 30% 25, >95 250]

TAIWAN EMI CNS 13438

KOREAN EMC No. 122

25/28

SD-R6112 Rev.1.0

Page 30
Image 30
Toshiba SD-R6112 specifications 25/28, Emergency Release, Safety Standards/Agency Approvals