General

Data

Table GD-1 – Model CVGF Description

Model

 

 

 

 

CVGF

 

 

Nominal Cooling Capacity

 

 

 

 

 

 

 

 

NTON

400

500

500

650

800

1000

Heat Exchanger Size

 

 

 

 

 

 

 

Evaporator

EVSZ

500

500

700

700

1000

1000

Condenser

CDSZ

500

500

700

700

1000

1000

Heat Exchanger Bundles

 

 

 

 

 

 

 

Evaporator

EVBS

A = Small

A = Small

A = Small

A = Small

A = Small

A = Small

 

 

B = Medium

B = Medium

B = Medium

B = Medium

B = Medium

B = Medium

 

 

C = Large

C = Large

C = Large

C = Large

C = Large

C = Large

 

 

 

 

 

 

D = Extra Large

D = Extra Large

Condenser

CDBS

A = Small

A = Small

A = Small

A = Small

A = Small

A = Small

 

 

B = Medium

B = Medium

B = Medium

B = Medium

B = Medium

B = Medium

 

 

C = Large

C = Large

C = Large

C = Large

C = Large

C = Large

 

 

 

 

 

 

D = Extra Large

D = Extra Large

Heat Exchanger Tube

 

 

 

 

 

 

 

Evaporator

EVTM

IE25 - 0.635 mm W 25.4 mm Internally Enhanced

 

 

 

 

 

(IE25 - 0.025” W 1.00” Internally Enhanced)

 

 

 

 

 

TE25 - 0.635 mm W19 mm Internally Enhanced

 

 

 

 

 

(TE25 - 0.025” W 0.75” Internally Enhanced)

 

 

 

Condenser

CDTM

IE28 - 0.711 mm W 25.4 mm Internally Enhanced

 

 

 

 

 

(IE28 - 0.028” W 1.00” Internally Enhanced)

 

 

 

 

 

TE28 - 0.711 mm W 19 mm Internally Enhanced

 

 

 

 

 

(TE28 - 0.028” W 0.75” Internally Enhanced)

 

 

 

Evap/Cond Working Pressure

 

 

 

 

 

 

 

bar

 

 

 

 

10

 

 

psi

 

 

 

 

150

 

 

Evap/Cond Water Connection

 

 

 

Victaulic Connection

 

 

 

 

 

 

 

 

 

 

 

 

Flanged Adaptor (English Unit)

 

 

 

 

 

 

Flanged Adaptor (SI Unit)

 

 

Agency Approvals (Chiller)

 

 

 

UL-CUL Listed/ASME

 

 

 

 

 

 

 

 

 

 

 

 

CE Approval/PED (European Code)

 

 

Motor Volt/Hz

 

 

 

380/400/415/3300/6600 Volts – 50 Hz

 

 

 

 

 

 

 

 

 

 

 

 

380/460/575/3300/4160 Volts – 60 Hz

 

 

Starter*

 

 

 

 

 

 

 

Unit Mounted

 

 

 

Wye-Delta, Solid-State Inside the Delta

 

 

Remote Mounted

 

 

Wye-Delta, Solid-State Inside the Delta, *Across-the-line, *Primary Reactor, *AutoTransformer

*Medium Voltage (3300, 4160, 6600) StarterTypes - Full Voltage (X-Line), Primary Reactor, AutoTransformer

Table GD-2 – Weight

 

 

 

 

 

Without Starter

 

 

With Starter

 

 

 

Shell Size

Operating

Shipping

Operating

Shipping

Model

Compressor

Evaporator

Condenser

lbs

kgs

lbs

kgs

lbs

kgs

lbs

kgs

CVGF

400 - 500

500

500

22391

10157

19656

8916

23336

10585

20601

9345

CVGF

500

700

700

29438

13353

25593

11609

30383

13782

26538

12038

CVGF

650

700

700

30889

14011

27044

12267

31765

14409

27920

12665

CVGF

800

1000

1000

41646

18891

35627

16160

42522

19288

36503

16558

CVGF

1000

1000

1000

42462

19261

36443

16531

43407

19689

37388

16959

**Note: Values represent estimate maximum unit weights including shells withTECU tubes, max bundles, 2 pass evaporator and condenser, 150 psig non- marine waterboxes, and compressors with the largest, low voltage motors for each family.

CTV-PRC001-GB

1 1

Page 11
Image 11
Trane CVGF manual General Data, Table GD-1 Model Cvgf Description

CVGF specifications

The Trane CVGF series is a revolutionary innovation in the world of commercial HVAC systems, designed to deliver unparalleled performance and energy efficiency. This air-cooled chiller line is specifically engineered to meet the demands of modern buildings, making it an ideal choice for various applications such as offices, hospitals, and educational institutions.

One of the standout features of the CVGF series is its use of the Trane Adaptive Control technology. This advancement provides the system with real-time data analytics, allowing it to automatically adjust cooling output based on environmental conditions and load requirements. This level of adaptability not only enhances occupant comfort but also contributes to significant energy savings, aligning with sustainability goals.

The CVGF chillers also incorporate a robust and efficient scroll compressor, which operates quietly and minimizes vibration. This design choice ensures reliability and longevity while reducing operational noise levels, making it suitable for installations in noise-sensitive environments. Furthermore, the scroll compressor's efficiency plays a crucial role in achieving a higher coefficient of performance (COP), which translates to lower energy costs.

In terms of environmental responsibility, the CVGF series is designed with an eco-friendly refrigerant that supports lower global warming potential (GWP). Committed to sustainability, Trane ensures that these chillers not only meet but exceed regulatory requirements, allowing businesses to operate with a reduced carbon footprint.

Another remarkable characteristic of the CVGF line is its modular design, which simplifies installation and maintenance. The units are compact and can be easily integrated into existing infrastructure, minimizing disruption during upgrades or replacements. The straightforward maintenance protocols further enhance the system’s uptime, ensuring users enjoy consistent and reliable cooling performance.

Moreover, the CVGF chillers are equipped with advanced monitoring capabilities, accessible through Trane’s proprietary software. This feature enables facility managers to oversee system performance from any location, facilitating proactive adjustments and timely maintenance interventions.

Overall, the Trane CVGF series stands out as a cutting-edge solution for effective and sustainable cooling in commercial applications. By combining innovative technologies, energy-efficient design, and user-friendly features, the CVGF offers a comprehensive approach to achieving optimal climate control while meeting the challenges of the future.