Image 6

Meter Panel

RX-208, RX-212

Graphic Equalizer (EQUALIZATION)

Two channel, 1/1 octave graphic equalizer with 9 bands (filters) enables 12dB of boost and attenuation at each center frequency with the "0" position of each filter providing

flat response. The graphic equalizer is

switchable to either the program or foldback outputs, or "off for A-B comparison.

Graphic Equalizer Selector Switch

(PGML, FB 1, OFF)

The 3-position switch assigns the equalizer to either the program L or FB 1 circuits, with the "off" position completely removing the equalizer from the signal flow path.

Program L Output Meter (PGM L)

The meter indicates the program L output level.

Program R Output Meter (PGM R)

The meter indicates the program R output

level.

FB 1 Output Meter (FB 1)

The meter indicates the FB 1 output level.

FB 2 Output Meter (FB 2)

The meter indicates the FB 2 output level.

Graphic Equalizer Selector Switch

(PGM R, FB 2, OFF)

The 3-position switch assigns the equalizer

to either the program R or FB 2 circuits, with

the "off" position completely removing the equalizer from the signal flow path.

Caution

The graphic equalizer is normally used for either the PGM or FB mix. For normal operation, only one button should be pressed. If the equalizer is not being used, the "OFF" button should be depressed.

RX-216

*The RX-216 is the same in its meter panel functions as the

RX-208 and RX-212.

FB 2 Output Meter

FB 1 Output Meter

 

Graphic Equalizer (EQUALIZATION)

Program R Output Meter

 

Program L Output Meter

Graphic Equalizer Selector Switch

Graphic Equalizer Selector Switch

(PGM L, FB 1, off)

(PGM R, FB 2, off)

- 5 -