Performance

 

Data

Air Handler

Table PD-31— Evaporator Fan Performance TWE075A (I-P)

 

 

 

 

 

 

 

External Static Pressure (In. Of Water Column)

 

 

 

 

 

 

 

 

 

 

0.10

0.20

0.30

0.40

0.50

0.60

0.70

0.80

0.90

1.00

1.10

 

CFM

RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP

2000

443

0.44

489

0.49

535

0.54

581

0.59

627

0.64

673

0.69

719

0.74

765

0.79

791

0.83

818

0.89

 

2125

453

0.46

499

0.52

546

0.57

592

0.63

638

0.68

684

0.74

730

0.79

771

0.85

798

0.90

825

0.96

 

2250

463

0.49

510

0.55

556

0.61

602

0.67

649

0.73

695

0.79

742

0.85

776

0.91

804

0.97

831

1.03

 

2375

473

0.51

520

0.57

567

0.64

613

0.70

660

0.77

706

0.83

753

0.90

782

0.97

810

1.03

838

1.10

 

2500

445

0.47

489

0.54

533

0.60

578

0.67

622

0.73

667

0.80

711

0.86

756

0.93

784

0.99

813

1.07

842

1.14

 

2625

464

0.50

506

0.57

548

0.63

589

0.69

631

0.76

672

0.82

714

0.88

757

0.95

786

1.01

815

1.09

844

1.17

 

2750

484

0.53

523

0.59

562

0.66

601

0.72

640

0.78

678

0.84

717

0.91

758

0.97

787

1.03

817

1.12

847

1.21

 

2875

504

0.56

540

0.62

576

0.68

612

0.74

648

0.81

684

0.87

720

0.93

759

0.99

789

1.05

819

1.15

850

1.24

 

3000

524

0.59

557

0.65

590

0.71

624

0.77

657

0.83

690

0.89

723

0.95

760

1.01

790

1.07

821

1.17

853

1.27

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1.0 HP Standard Motor

 

 

 

 

1.0 HP Standard Motor

 

 

 

 

1.5 HP Oversized Motor

 

and Low Static Drive

 

 

 

 

 

andDrive

 

 

 

 

 

and High Static Drive

Notes:

1.Performance based on a wet coil and 1 inch (25.4 mm) throwaway filters.

2.Tabulated brake horsepower is the motor shaft output required.

3.Factory setting of motor sheave is 1.5 turns open. Adjustments are made in 0.5 turn increments.

Table PD-29 — Continued

External Static Pressure (In. Of Water Column)

1.20 1.30 1.40 1.50 1.60 CFM RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP

2000 844 0.96 871 1.02 897 1.09 924 1.15 950 1.21 2125 852 1.03 879 1.09 906 1.16 933 1.22 — — 2250 859 1.10 886 1.17 914 1.23 942 1.30 — — 2375 866 1.17 894 1.24 922 1.30 950 1.37 — — 2500 870 1.21 899 1.29 928 1.36 — — — —

2625 874 1.25 903 1.33 932 1.42 — — — —

2750 877 1.29 907 1.38 937 1.47 — — — —

2875 880 1.33 911 1.43 942 1.52 — — — —

3000 884 1.37 915 1.48 946 1.58 — — — —

1.5HP Oversized Motor and High Static Drive

1.0HP Standard Motor

andDrive

Table PD-31 — Evaporator Fan Performance TWE075A (SI)

 

 

 

 

 

 

 

 

External Static Pressure (Pascal)

 

 

 

 

 

 

 

 

 

 

 

25

50

75

100

125

150

174

199

 

224

249

274

 

m3/hr

RPM

kW

RPM

kW

RPM

kW

RPM kW RPM kW RPM kW RPM kW RPM kW RPM kW RPM kW RPM kW

3338

443

0.33

489

0.37

535

0.4

581

0.44

627

0.48

673

0.51

719

0.55

765

0.59

791

0.62

818

0.66

 

3547

453

0.34

499

0.39

546

0.43

592

0.47

638

0.51

684

0.55

730

0.59

771

0.63

798

0.67

825

0.72

 

3755

463

0.37

510

0.41

556

0.45

602

0.5

649

0.54

695

0.59

742

0.63

776

0.68

804

0.72

831

0.77

 

3964

473

0.38

520

0.43

567

0.48

613

0.52

660

0.57

706

0.62

753

0.67

782

0.72

810

0.77

838

0.82

 

4173

445

0.35

489

0.4

533

0.45

578

0.5

622

0.54

667

0.6

711

0.64

756

0.69

784

0.74

813

0.8

842

0.85

 

4381

464

0.37

506

0.43

548

0.47

589

0.51

631

0.57

672

0.61

714

0.66

757

0.71

786

0.75

815

0.81

844

0.87

 

4590

484

0.4

523

0.44

562

0.49

601

0.54

640

0.58

678

0.63

717

0.68

758

0.72

787

0.77

817

0.84

847

0.9

 

4798

504

0.42

540

0.46

576

0.51

612

0.55

648

0.6

684

0.65

720

0.69

759

0.74

789

0.78

819

0.86

850

0.92

 

5007

524

0.44

557

0.48

590

0.53

624

0.57

657

0.62

690

0.66

723

0.71

760

0.75

790

0.8

821

0.87

853

0.95

 

 

.75 kW Standard Motor

 

 

 

.75 kW Standard Motor

 

 

 

1.12 kW Oversized

Motor

 

and Low Static Drive

 

 

 

 

 

and Drive

 

 

 

 

 

and High Static Drive

Notes:

1.Performance based on a wet coil and 1 inch (25.4 mm) throwaway filters.

2.Tabulated brake horsepower is the motor shaft output required.

3.Factory setting of motor sheave is 1.5 turns open. Adjustments are made in 0.5 turn increments.

Table PD-32 — Blower Speeds — TWE075A

 

 

 

Motor DriveTurns Open

 

 

Drive

6

5

4

3

2

1

0

Standard

N/A

600

650

700

750

800

850

Low Static

N/A

428

464

499

535

571

606

High Static

N/A

700

750

800

850

900

950

SS-PRC003-EN

Table PD-31 — Continued

 

 

External Static Pressure (Pascal)

 

 

 

299

324

349

374

398

m3/hr

RPM kW RPM kW RPM kW RPM kW RPM kW

3338

844

0.72

871

0.76

897

0.81

924

0.86

950

0.9

3547

852

0.77

879

0.81

906

0.87

933

0.91

3755

859

0.82

886

0.87

914

0.92

942

0.97

3964

866

0.87

894

0.92

922

0.97

950

1.02

4173

870

0.9

899

0.96

928

1.01

 

 

 

 

4381

874

0.93

903

0.99

932

1.06

 

4590

877

0.96

907

1.03

937

1.1

 

4798

880

0.99

911

1.07

942

1.13

 

5007

884

1.02

915

1.1

946

1.18

 

 

1.12 kW Oversized Motor and High Static Drive

.75 kW Standard Motor

andDrive

43

Page 43
Image 43
Trane SS-PRC003-EN Table PD-31- Evaporator Fan Performance TWE075A I-P, Table PD-29, Table PD-32 Blower Speeds TWE075A

SS-PRC003-EN specifications

The Trane SS-PRC003-EN is a high-efficiency commercial HVAC solution designed to cater to a wide variety of industrial applications. Known for its robust engineering and innovative design, this unit provides reliable climate control, ensuring optimal indoor environments in commercial spaces, manufacturing plants, and large facilities.

One of the standout features of the SS-PRC003-EN is its advanced inverter technology. This variable-speed compressor allows for precise cooling and heating adjustments based on real-time demand, which not only enhances system efficiency but also significantly reduces energy consumption. This capability not only minimizes operational costs but also contributes to a more sustainable energy profile, aligning with growing environmental concerns.

Another notable characteristic is its user-friendly control system. The unit is equipped with intuitive interfaces that allow facility managers to monitor and adjust settings remotely. This functionality ensures optimal performance, facilitates maintenance, and offers diagnostics that help identify potential issues before they lead to system failure.

Moreover, the SS-PRC003-EN features a built-in air filtration system that improves indoor air quality. It effectively removes dust, pollutants, and allergens from the air, contributing to healthier environments for occupants. This is particularly critical in commercial settings where many individuals congregate, ensuring compliance with health and safety regulations.

The design also emphasizes noise reduction technology. The unit operates at whisper-quiet levels, minimizing disruption in work environments and enhancing comfort for occupants. This is achieved through a combination of sound-absorbing materials and engineered airflow paths.

Additionally, the Trane SS-PRC003-EN is constructed with durability in mind. It resists corrosion, withstands harsh environmental conditions, and maintains performance longevity, making it a reliable choice for facilities that require constant operation.

With its combination of efficiency, advanced technology, user-friendly controls, and superior air quality management, the Trane SS-PRC003-EN stands out as a market leader in commercial HVAC systems. It offers businesses the performance they need while also promoting energy savings and environmental stewardship, making it an invaluable addition to any commercial infrastructure.