Performance

 

Data

Condensing Unit

Table PD-23 — Cooling Performance (MBh)

TTA125B Condensing Unit Only (I-P)

ODTemp

 

 

 

Suction ReferenceTemperature °F

°F

 

30

35

40

45

50

55

 

Head press PSIG

175

181

187

193

200

207

65

Cap. Btuh/1000

116.6

128.0

139.9

152.2

164.9

178.1

 

OD Unit KW

8.04

8.25

8.47

8.70

8.95

9.20

 

Head press PSIG

201

207

214

221

228

235

75

Cap. Btuh/1000

111.2

122.1

133.4

145.2

157.5

170.0

 

OD Unit KW

8.83

9.06

9.29

9.53

9.79

10.06

 

Head press PSIG

230

237

244

251

259

267

85

Cap. Btuh/1000

105.6

116.0

126.9

138.1

149.8

161.8

 

OD Unit KW

9.73

9.97

10.22

10.48

10.75

11.02

 

Head press PSIG

262

269

276

284

292

300

95

Cap. Btuh/1000

99.9

109.7

120.0

130.8

141.8

153.2

 

OD Unit KW

10.73

10.98

11.25

11.52

11.80

12.09

 

Head press PSIG

296

304

311

320

328

337

105

Cap. Btuh/1000

94.0

103.2

113.0

123.1

133.6

144.5

 

OD Unit KW

11.83

12.09

12.37

12.66

12.95

13.26

 

Head press PSIG

334

341

349

358

367

376

115

Cap. Btuh/1000

87.9

96.6

105.7

115.2

125.2

135.5

 

OD Unit KW

13.02

13.30

13.59

13.89

14.20

14.52

Performance Data Calculated at 15 deg. subcooling and 15 deg. superheat.

Table PD-23 — Cooling Performance (kW)

TTA125B Condensing Unit Only (SI)

ODTemp

 

 

 

Suction ReferenceTemperature °C

°C

 

-1.1

1.7

4.4

7.2

10.0

12.8

 

Head pressure (kPA)

1205

1245

1287

1331

1377

1425

18.3

Capacity (kW)

34.1

37.5

41.0

44.6

48.3

52.1

 

OD Unit Power (kW)

8.04

8.25

8.47

8.70

8.95

9.20

 

Head pressure (kPA)

1387

1430

1474

1521

1571

1623

23.9

Capacity (kW)

32.6

35.8

39.1

42.5

46.1

49.8

 

OD Unit Power (kW)

8.83

9.06

9.29

9.53

9.79

10.06

 

Head pressure (kPA)

1587

1633

1681

1731

1783

1838

29.4

Capacity (kW)

30.9

34.0

37.2

40.4

43.9

47.4

 

OD Unit Power (kW)

9.73

9.97

10.22

10.48

10.75

11.02

 

Head pressure (kPA)

1806

1855

1905

1958

2013

2071

35.0

Capacity (kW)

29.2

32.1

35.2

38.3

41.5

44.9

 

OD Unit Power (kW)

10.73

10.98

11.25

11.52

11.80

12.09

 

Head pressure (kPA)

2044

2095

2148

2203

2261

2322

40.6

Capacity (kW)

27.5

30.2

33.1

36.0

39.1

42.3

 

OD Unit Power (kW)

11.83

12.09

12.37

12.66

12.95

13.26

 

Head pressure (kPA)

2301

2354

2409

2466

2527

2591

46.1

Capacity (kW)

25.7

28.3

30.9

33.7

36.7

39.7

 

OD Unit Power (kW)

13.02

13.30

13.59

13.89

14.20

14.52

Performance Data Calculated at 8.3 deg. subcooling and 8.3 deg. superheat.

36

SS-PRC003-EN

Page 36
Image 36
Trane SS-PRC003-EN TTA125B Condensing Unit Only I-P, TTA125B Condensing Unit Only SI, Table PD-23 Cooling Performance MBh

SS-PRC003-EN specifications

The Trane SS-PRC003-EN is a high-efficiency commercial HVAC solution designed to cater to a wide variety of industrial applications. Known for its robust engineering and innovative design, this unit provides reliable climate control, ensuring optimal indoor environments in commercial spaces, manufacturing plants, and large facilities.

One of the standout features of the SS-PRC003-EN is its advanced inverter technology. This variable-speed compressor allows for precise cooling and heating adjustments based on real-time demand, which not only enhances system efficiency but also significantly reduces energy consumption. This capability not only minimizes operational costs but also contributes to a more sustainable energy profile, aligning with growing environmental concerns.

Another notable characteristic is its user-friendly control system. The unit is equipped with intuitive interfaces that allow facility managers to monitor and adjust settings remotely. This functionality ensures optimal performance, facilitates maintenance, and offers diagnostics that help identify potential issues before they lead to system failure.

Moreover, the SS-PRC003-EN features a built-in air filtration system that improves indoor air quality. It effectively removes dust, pollutants, and allergens from the air, contributing to healthier environments for occupants. This is particularly critical in commercial settings where many individuals congregate, ensuring compliance with health and safety regulations.

The design also emphasizes noise reduction technology. The unit operates at whisper-quiet levels, minimizing disruption in work environments and enhancing comfort for occupants. This is achieved through a combination of sound-absorbing materials and engineered airflow paths.

Additionally, the Trane SS-PRC003-EN is constructed with durability in mind. It resists corrosion, withstands harsh environmental conditions, and maintains performance longevity, making it a reliable choice for facilities that require constant operation.

With its combination of efficiency, advanced technology, user-friendly controls, and superior air quality management, the Trane SS-PRC003-EN stands out as a market leader in commercial HVAC systems. It offers businesses the performance they need while also promoting energy savings and environmental stewardship, making it an invaluable addition to any commercial infrastructure.