Performance

 

Data

Air Handler

Table PD-33 — Evaporator Fan Performance TWE100A, TWE100B (I-P)

 

 

 

 

 

 

 

 

External Static Pressure (In. Of Water Column)

 

 

 

 

 

 

 

 

0.10

0.20

0.30

0.40

0.50

0.60

0.70

0.80

0.90

1.00

1.20

CFM

RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP

1.5 HP Standard Motor and Low Static Drive

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2600

460

0.32

493

0.39

527

0.47

565

0.55

603

0.63

641

0.71

679

0.79

717

0.87

744

0.94

772

1.01

826

1.16

2775

473

0.37

506

0.45

540

0.53

576

0.61

613

0.69

649

0.77

686

0.85

723

0.93

748

1.00

775

1.07

830

1.20

2950

487

0.43

519

0.50

552

0.58

587

0.67

 

623

0.75

658

0.83

693

0.91

728

0.99

751

1.06

779

1.12

833

1.25

3125

501

0.49

532

0.56

565

0.64

599

0.72

632

0.81

666

0.89

700

0.97

734

1.05

755

1.11

783

1.18

737

1.30

3300

520

0.58

548

0.65

581

0.73

 

613

0.81

644

0.89

677

0.98

710

1.06

740

1.13

759

1.19

787

1.25

841

1.37

3475

541

0.69

568

0.76

600

0.84

631

0.93

658

1.00

691

1.08

721

1.16

746

1.21

764

1.28

793

1.34

846

1.48

3650

562

0.82

588

0.88

618

0.97

648

1.05

671

1.11

703

1.19

732

1.27

753

1.31

772

1.38

801

1.45

853

1.59

3825

582

0.96

608

1.03

637

1.11

666

1.20

685

1.26

711

1.31

739

1.38

763

1.44

787

1.51

815

1.58

862

1.74

4000

602

1.11

628

1.17

656

1.26

683

1.35

698

1.40

720

1.43

747

1.50

773

1.58

801

1.64

829

1.71

872

1.89

 

 

 

 

 

 

 

 

1.5 HP Standard Motor and Drive

 

 

 

2.0 HP Oversized Motor

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

and High Static Drive

Notes:

1.Performance based on a wet coil and 1 inch (25.4 mm) throwaway filters.

2.Tabulated brake horsepower is the motor shaft output required.

3.Factory setting of motor sheave is 1.5 turns open. Adjustments are made in 0.5 turn increments.

4.Low Static Drive must be field supplied.

Table PD-33— Evaporator Fan Performance TWE0100A, TWE100B (SI)

Table PD-33— Continued

External Static Pressure (In. Of Water Column)

1.401.60

CFM RPM BHP RPM BHP

2.0HP Oversized Motor and High Static Drive

2600 881 1.30 936 1.45

2775 884 1.36 938 1.51

2960 886 1.41 939 1.57

3125 889 1.47 941 1.64

3300 892 1.54 945 1.73

3475 897 1.63 950 1.85

3650 902 1.73 955 1.99

3825 912 1.89 960 2.18

4000 922 2.04 965 2.30

 

 

 

 

 

 

 

 

External Static Pressure (Pascal)

 

 

 

 

 

 

 

 

 

 

25

50

75

100

125

150

174

199

224

249

299

m3/hr

RPM

kW

RPM kW RPM kW RPM kW RPM kW RPM kW RPM kW

RPM

kW

RPM

kW

RPM

kW

RPM

kW

1.12 kW Standard Motor and Low Static Drive

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4417

460

0.24

493

0.29

527

0.35

565

0.41

603

0.47

641

0.53

679

0.59

717

0.65

744

0.7

772

0.75

826

0.87

4715

473

0.28

506

0.34

540

0.4

576

0.45

613

0.51

649

0.57

686

0.63

723

0.69

748

0.75

775

0.8

830

0.89

5012

487

0.32

519

0.37

552

0.43

587

0.5

623

0.56

658

0.62

693

0.68

728

0.74

751

0.79

779

0.84

833

0.93

5309

501

0.37

532

0.42

565

0.48

599

0.54

632

0.6

666

0.66

700

0.72

734

0.78

755

0.83

783

0.88

737

0.97

5607

520

0.43

548

0.48

581

0.54

613

0.6

644

0.66

677

0.73

710

0.79

740

0.84

759

0.89

787

0.93

841

1.02

5904

541

0.51

568

0.57

 

600

0.63

631

0.69

658

0.75

691

0.8

721

0.87

746

0.9

764

0.95

793

1

846

1.1

6201

562

0.61

588

0.66

618

0.72

648

0.78

671

0.83

703

0.89

732

0.95

753

0.98

772

1.03

801

1.08

853

1.19

6499

582

0.72

608

0.77

637

0.83

666

0.89

685

0.94

711

0.98

739

1.03

763

1.07

787

1.13

815

1.18

862

1.3

6796

602

0.83

628

0.87

656

0.94

683

1.01

698

1.04

720

1.07

747

1.12

773

1.18

801

1.22

829

1.28

872

1.41

 

 

 

 

 

 

 

1.12 kW Standard Motor and Drive

 

 

 

1.49 kW Oversized Motor

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

and High Static Drive

Notes:

1.Performance based on a wet coil and 1 inch (25.4 mm) throwaway filters.

2.Tabulated brake horsepower is the motor shaft output required.

3.Factory setting of motor sheave is 3.0 turns open. Adjustments are made in 0.5 turn increments.

4.Low Static Drive must be field supplied.

Table PD-34 — Blower Speeds — TWE100A, TWE100B

 

 

 

Motor SheaveTurns Open

 

 

Drive

6

5

4

3

2

1

0

Standard

N/A

587

629

671

713

755

796

Low Static

N/A

453

485

518

550

583

615

High Static

N/A

606

641

677

713

748

784

High Static II N/A

745

789

833

877

920

965

44

Table PD-33— Continued

External Static Pressure (Pascal)

349398

m3/hr RPM kW RPM kW

1.49kW Oversized Motor and High Static Drive

4417 881 0.97 936 1.08

4715 884 1.01 938 1.13

5012 886 1.05 939 1.17

5309 889 1.1 941 1.22

5607 892 1.15 945 1.29

5904 897 1.22 950 1.38

6201 902 1.29 955 1.48

6499 912 1.41 960 1.63

6796 922 1.52 965 1.72

SS-PRC003-EN

Page 44
Image 44
Trane SS-PRC003-EN Table PD-33 Evaporator Fan Performance TWE100A, TWE100B I-P, Table PD-34 Blower Speeds TWE100A, TWE100B

SS-PRC003-EN specifications

The Trane SS-PRC003-EN is a high-efficiency commercial HVAC solution designed to cater to a wide variety of industrial applications. Known for its robust engineering and innovative design, this unit provides reliable climate control, ensuring optimal indoor environments in commercial spaces, manufacturing plants, and large facilities.

One of the standout features of the SS-PRC003-EN is its advanced inverter technology. This variable-speed compressor allows for precise cooling and heating adjustments based on real-time demand, which not only enhances system efficiency but also significantly reduces energy consumption. This capability not only minimizes operational costs but also contributes to a more sustainable energy profile, aligning with growing environmental concerns.

Another notable characteristic is its user-friendly control system. The unit is equipped with intuitive interfaces that allow facility managers to monitor and adjust settings remotely. This functionality ensures optimal performance, facilitates maintenance, and offers diagnostics that help identify potential issues before they lead to system failure.

Moreover, the SS-PRC003-EN features a built-in air filtration system that improves indoor air quality. It effectively removes dust, pollutants, and allergens from the air, contributing to healthier environments for occupants. This is particularly critical in commercial settings where many individuals congregate, ensuring compliance with health and safety regulations.

The design also emphasizes noise reduction technology. The unit operates at whisper-quiet levels, minimizing disruption in work environments and enhancing comfort for occupants. This is achieved through a combination of sound-absorbing materials and engineered airflow paths.

Additionally, the Trane SS-PRC003-EN is constructed with durability in mind. It resists corrosion, withstands harsh environmental conditions, and maintains performance longevity, making it a reliable choice for facilities that require constant operation.

With its combination of efficiency, advanced technology, user-friendly controls, and superior air quality management, the Trane SS-PRC003-EN stands out as a market leader in commercial HVAC systems. It offers businesses the performance they need while also promoting energy savings and environmental stewardship, making it an invaluable addition to any commercial infrastructure.