Installer’s Guide

l

;SUPPORT HORIZONTAL PIPE EVERY 3' 0" WITH THE FIRST SUPPORT AS CLOSE TO THE FURNACE AS POSSIBLE. INDUCED DRAFT BLOWER, HOUSING, AND FURNACE MUST NOT SUPPORT THE WEIGHT OF THE FLUE PIPE.

z

COMBUSTION

AIR INLET

40" UPFLOW OR DOWNFLOW MODELS

SEE VENTING TABLE

STRAPS OR OTHER SUITABLE SUPPORTS AT MAXIMUM OF 3'-0" INTERVALS

UPWARD PITCH -- 1/4" PER FOOT

FIRST SUPPORT SHOULD BE AS

CLOSE TO FURNACE CONNECTION

AS POSSIBLE.

NOTE: ANY FITTINGS PASSING

THROUGH AN UNHEATED SPACE

MUST BE INSULATED.

NOTE: VENT AND INLET MUST BE SUPPORTED

AT A MAXIMUM OF 3' INTERVALS

USE ONLY

APPROVED

TERMINATION

OUTSIDE

WALL

STRAP (FIELD SUPPLIED)

TEE

COMBUSTION

REDUCING

AIR

COUPLING,

 

RAIN CAP

FIELD SUPPLIED

IF NEEDED

 

VENT

COMBUSTION AIR

ELBOW (FIELD SUPPLIED)

VENT

2", 2-1/2"

or 3" PIPING

 

1" + 1/2"

 

 

3" PIPING

 

SEAL ALL

BAYAIR30AVENTA

BAYVENT200B

WALL CAVITIES

 

18-CD22D1-8

21

Page 21
Image 21