9.The horizontal installation of the upflow furnace requires an external filter section. Do NOT use the bottom return filter within the furnace. Filter kits are available for horizon- tal applications.

10.Connect duct work to furnace. See Outline Drawing for supply and return duct size and location. Flex- ible duct connectors are recommended to connect both supply and return air ducts to the furnace. If only the front of the furnace is accessible, it is recommended that both supply and return air plenums are removable.

RETURN AIR FILTERS

TYPICAL UPFLOW RETURN

AIR FILTER INSTALLATIONS

furnaces require high velocity type air filters. The filters may be installed within the furnace blower compartment for UPFLOW furnaces in either a BOT- TOM or SIDE (left side or right side) return air inlet. Some filters may need to be trimmed for side or bottom filter use.

0UPFLOW FURNACE ONLY

LOCATING

CUT

OUT

NOTCHES PRO-

FOR

SIDE

VIDED FOR SIDE

FILTER

RETURN CUTOUT

 

 

FRONT

of Furnace

*SEE OUTLINE DRAWING

q

Installer’s Guide

TABLE 3

MODELS

CABINET

FILTER

 

NUMBERS

WIDTH

QTY & SIZE

 

*UX1B040A9H21B

 

 

 

*UX1B060A9H31B

17-1/2"

1 - 17" X 25" X

1"

*UX1B080A9H31B

 

 

 

*UX1C100A9H41B

21"

1 - 20" X 25" X 1"

 

 

 

 

*UX1D120A9H51B

24-1/2"

1 - 24" X 25" X

1"

 

 

 

 

*First letter may be "A" or "T"

**NOTE: For upflow 5 ton airflow models where the airflow requirement exceeds 1800 CFM - Modles will require return air openings and filters on: (1) both sides, or (2) one side and the bottom, or (3) just on the bottom

NOTE: For upflow 5 ton airflow models where the airflow requirement exceeds 1800 CFM - Models will require return air openings and filters on: (1) both sides, or (2)1 side and the bottom, or (3) just the bottom.

The furnace and the bottom filter rack installation can be seen in Figure 11.

The furnace filter in the bottom or side configuration can be removed by simply turning the two latches on the blower door and tilting the door forward.

OPTIONAL FILTER RACK INSTALLATION FOR BOT- TOM RETURN

The following checklist should be used when installing a bottom return filter on an upflow furnace:

a. Remove the filter.

b. Remove the filter rack.

c. Remove the bottom panel.

e. With the filter removed, the filter rack is com- pressed and then inserted into the bottom of the furnace. The retaining screw/pin on each side inserts into engagement holes at the bottom of the furnace cabinet side. See Figure 12.

f.Reinstall the furnace filter in the bottom posi- tion by inserting the chamfer end first into the filter rack

Airf low

BOTTOM FILTER RACK INSTALLATION

w

Furnace

Cabinet

Side

Engagement Hole

For Filter Rack

Installation With

Bottom Return

Filter Rack

Retaining

Screw/Pin Filter

Rack

Bottom Panel

18-CD22D1-8

11

Page 11
Image 11
Trane UX1B080A9H31B, UX1C100A9H41B Return AIR Filters, Typical Upflow Return AIR Filter Installations, Upflow Furnace only