XT302C DELUXE PROGRAMMABLE HEAT-COOL THERMOSTAT

Table 3. Installer Setup Options for the XT302C (continued).

 

Press Time

 

Press Increase or Decrease to change setting

 

 

or

 

 

 

Installer

Factory Setting

 

Other Choices

Actual

Select

Setup Number

Display

 

Description

Display

Description

Setting

Minimum On

33

10

 

10-minute minimum on

0 thru 15

Minimum number of minutes

 

Time (Cool)

 

 

 

time for compressor

 

(0 thru 15) the compressor

 

 

 

 

 

 

 

will be on during call for

 

 

 

 

 

 

 

cool

 

 

 

 

 

 

 

 

 

Temperature

34

85

 

Highest setpoint

55 to 85

Temperature range (1°F

 

range stops in

 

 

 

heating can be set to

 

increments) heating

 

heating

 

 

 

 

 

setpoint can be set to

 

 

 

 

 

 

 

 

 

Temperature

35

65

 

Lowest setpoint

65 to 99

Temperature range (1°F

 

range stops in

 

 

 

cooling can be set to

 

increments) cooling

 

cooling

 

 

 

 

 

setpoint can be set to

 

 

 

 

 

 

 

 

 

Temperature

37

0

 

No difference

3, 2, 1, -1,

3—Display adjusts to 3 °F

 

display

 

 

 

in displayed

-2, or

higher than actual room

 

adjustment

 

 

 

temperature and

-3

temperature

 

 

 

 

 

actual room

 

2—Display adjusts to 2 °F

 

 

 

 

 

temperature

 

higher than actual room

 

 

 

 

 

 

 

temperature

 

 

 

 

 

 

 

1—Display adjusts to 1 °F

 

 

 

 

 

 

 

higher than actual room

 

 

 

 

 

 

 

temperature

 

 

 

 

 

 

 

-1—Display adjusts to 1 °F

 

 

 

 

 

 

 

lower than actual room

 

 

 

 

 

 

 

temperature

 

 

 

 

 

 

 

-2—Display adjusts to 2 °F

 

 

 

 

 

 

 

lower than actual room

 

 

 

 

 

 

 

temperature

 

 

 

 

 

 

 

-3—Display adjusts to 3 °F

 

 

 

 

 

 

 

lower than actual room

 

 

 

 

 

 

 

temperature

 

 

 

 

 

 

 

 

 

Minimum Off

38

5

 

5 minute minimum off

0 thru 15

Minimum number of minutes

 

Time (Heat)

 

 

 

time for the

 

(0 thru 15) the compressor

 

 

 

 

 

compressor

 

will be off between calls for

 

 

 

 

 

 

 

heat

 

 

 

 

 

 

 

 

 

Minimum Off

39

5

 

5 minute minimum off

0 thru 15

Minimum number of minutes

 

Time (Cool)

 

 

 

time for the

 

(0 thru 15) the compressor

 

 

 

 

 

compressor

 

will be off between calls for

 

 

 

 

 

 

 

cool

 

 

 

 

 

 

 

 

 

Cooling Droop

41

1

 

Cooling droop

0

No cooling droop

 

 

 

 

 

activated

 

 

 

 

 

 

 

 

 

 

 

Programming

42

0

 

7-day programming

1 or 2

1—24-hour programming

 

 

Press Time to

 

 

 

 

2—No programming

 

 

bypass 2–41

 

 

 

 

 

 

 

and go directly

 

 

 

 

 

 

 

to setup #42

 

 

 

 

 

 

 

 

 

 

 

 

 

 

IMPORTANT

Review the settings to confirm that they match the system. Press Run Program to exit the Installer Setup. The thermostat saves the Installer Setup changes and initiates a reset in order to operate using the new settings.

NOTE: For initial installations only, set the current day and time following the setup reset.

Setting Current Day and Time

1. Press Set Current Day/Time.

Set Current

 

 

 

 

 

 

 

PM

Program

Day/Time

 

Wake

Leave

Return

Sleep

Mon

 

Run

Set Current

 

 

 

 

 

 

Day/Time

 

 

Time

 

Set Program

 

 

Hold Temp

Day

 

Settings

Filter

System

Fan

 

 

 

 

 

Heat/Cool

 

 

 

 

 

 

Daylight

Copy

 

 

 

 

 

 

 

Time

 

 

 

 

 

M12951

NOTE: On initial power up or after an extended power loss, 1:00 pm flashes on the display until a key is pressed.

Pub. No. 18-HD25D7-5

7

69-1213—1 (T8624)