XT302C DELUXE PROGRAMMABLE HEAT-COOL  THERMOSTAT
Table 3. Installer Setup Options for the XT302C (continued).
| 
 | Press Time | 
 | Press Increase ▲ or Decrease ▼ to change setting | 
 | |||
| 
 | ▲ or ▼ | 
 | 
 | ||||
| 
 | Installer | Factory Setting | 
 | Other Choices | Actual | ||
| Select | Setup Number | Display | 
 | Description | Display | Description | Setting | 
| Adaptive | 13 | 0 | 
 | Adaptive Intelligent | 1 | Conventional recovery | 
 | 
| Intelligent | 
 | 
 | 
 | Recovery (a | 
 | (system starts recovery at | 
 | 
| Recovery™ | 
 | 
 | 
 | Honeywell trademark) | 
 | programmed time) | 
 | 
| control | 
 | 
 | 
 | control is activated | 
 | 
 | 
 | 
| 
 | 
 | 
 | 
 | (system starts early so | 
 | 
 | 
 | 
| 
 | 
 | 
 | 
 | setpoint is reached by | 
 | 
 | 
 | 
| 
 | 
 | 
 | 
 | start of program | 
 | 
 | 
 | 
| 
 | 
 | 
 | 
 | period) | 
 | 
 | 
 | 
| 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
| Degree | 14 | 0 | 
 | Temperature displays | 1 | Temperature displays in °C | 
 | 
| temperature | 
 | 
 | 
 | in °F | 
 | 
 | 
 | 
| display | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
| 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
| Clock format | 16 | 0 | 
 | 1 | 
 | ||
| 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
| Extended fan | 19 | 0 | 
 | No extended fan | 1, 2 or 3 | 
 | |
| operation in | 
 | 
 | 
 | operation after the call | 
 | 30 seconds after the call | 
 | 
| heatinga | 
 | 
 | 
 | for heat ends | 
 | ends. | 
 | 
| 
 | 
 | 
 | 
 | 
 | 
 | 
 | |
| 
 | 
 | 
 | 
 | 
 | 
 | 60 seconds after the call | 
 | 
| 
 | 
 | 
 | 
 | 
 | 
 | ends. | 
 | 
| 
 | 
 | 
 | 
 | 
 | 
 | 3  | 
 | 
| 
 | 
 | 
 | 
 | 
 | 
 | 90 seconds after the call | 
 | 
| 
 | 
 | 
 | 
 | 
 | 
 | ends. | 
 | 
| 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
| Extended fan | 20 | 0 | 
 | No extended fan | 1, 2 or 3 | 
 | |
| operation in | 
 | 
 | 
 | operation after the | 
 | 30 seconds after the call | 
 | 
| cooling | 
 | 
 | 
 | call for cool ends | 
 | ends. | 
 | 
| 
 | 
 | 
 | 
 | 
 | 
 | 
 | |
| 
 | 
 | 
 | 
 | 
 | 
 | 60 seconds after the call | 
 | 
| 
 | 
 | 
 | 
 | 
 | 
 | ends. | 
 | 
| 
 | 
 | 
 | 
 | 
 | 
 | 3  | 
 | 
| 
 | 
 | 
 | 
 | 
 | 
 | 90 seconds after the call | 
 | 
| 
 | 
 | 
 | 
 | 
 | 
 | ends. | 
 | 
| 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
| Outdoor | 24 | 0 | 
 | No outdoor | 1 | Outdoor temperature | 
 | 
| temperature | 
 | 
 | 
 | temperature displays | 
 | displays. Requires a | 
 | 
| display (select | 
 | 
 | 
 | 
 | 
 | TAYSENS100A Outdoor | 
 | 
| models) | 
 | 
 | 
 | 
 | 
 | Sensor. | 
 | 
| 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
| 28 | 0 | 
 | No fan delay | 1 or 2 | 
 | ||
| Enable | 
 | 
 | 
 | 
 | 
 | 
 | |
| 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
| Minimum | 30 | 4 | 
 | Heating and cooling | 3 thru 10 | Heating and cooling | 
 | 
| Deadband | 
 | 
 | 
 | setpoints can be set | 
 | setpoints can be set no | 
 | 
| Between | 
 | 
 | 
 | no closer than 4°F | 
 | closer than the chosen | 
 | 
| Heating and | 
 | 
 | 
 | (2°C) | 
 | value: | 
 | 
| Cooling in Auto | 
 | 
 | 
 | 
 | 
 | 
 | |
| Changeover | 
 | 
 | 
 | 
 | 
 | 
 | |
| Mode | 
 | 
 | 
 | 
 | 
 | 
 | |
| 
 | 
 | 
 | 
 | 
 | 
 | 
 | |
| 
 | 
 | 
 | 
 | 
 | 
 | 
 | |
| 
 | 
 | 
 | 
 | 
 | 
 | 
 | |
| 
 | 
 | 
 | 
 | 
 | 
 | 
 | |
| 
 | 
 | 
 | 
 | 
 | 
 | 
 | |
| 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
| Minimum On | 32 | 5 | 
 | 0 thru 15 | Minimum number of minutes | 
 | |
| Time (Heat) | 
 | 
 | 
 | time for compressor | 
 | (0 thru 15) the compressor | 
 | 
| 
 | 
 | 
 | 
 | 
 | 
 | will be on during call for | 
 | 
| 
 | 
 | 
 | 
 | 
 | 
 | heat | 
 | 
| 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
| 
 | 
 | 
 | 
 | 
 | 
 | 
 | (continued) | 
Pub. No. 
| 6 | 