XT302C DELUXE PROGRAMMABLE HEAT-COOL THERMOSTAT
Table 3. Installer Setup Options for the XT302C (continued).
| Press Time |
| Press Increase ▲ or Decrease ▼ to change setting |
| |||
| ▲ or ▼ |
|
| ||||
| Installer | Factory Setting |
| Other Choices | Actual | ||
Select | Setup Number | Display |
| Description | Display | Description | Setting |
Adaptive | 13 | 0 |
| Adaptive Intelligent | 1 | Conventional recovery |
|
Intelligent |
|
|
| Recovery (a |
| (system starts recovery at |
|
Recovery™ |
|
|
| Honeywell trademark) |
| programmed time) |
|
control |
|
|
| control is activated |
|
|
|
|
|
|
| (system starts early so |
|
|
|
|
|
|
| setpoint is reached by |
|
|
|
|
|
|
| start of program |
|
|
|
|
|
|
| period) |
|
|
|
|
|
|
|
|
|
|
|
Degree | 14 | 0 |
| Temperature displays | 1 | Temperature displays in °C |
|
temperature |
|
|
| in °F |
|
|
|
display |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Clock format | 16 | 0 |
| 1 |
| ||
|
|
|
|
|
|
|
|
Extended fan | 19 | 0 |
| No extended fan | 1, 2 or 3 |
| |
operation in |
|
|
| operation after the call |
| 30 seconds after the call |
|
heatinga |
|
|
| for heat ends |
| ends. |
|
|
|
|
|
|
|
| |
|
|
|
|
|
| 60 seconds after the call |
|
|
|
|
|
|
| ends. |
|
|
|
|
|
|
| 3 |
|
|
|
|
|
|
| 90 seconds after the call |
|
|
|
|
|
|
| ends. |
|
|
|
|
|
|
|
|
|
Extended fan | 20 | 0 |
| No extended fan | 1, 2 or 3 |
| |
operation in |
|
|
| operation after the |
| 30 seconds after the call |
|
cooling |
|
|
| call for cool ends |
| ends. |
|
|
|
|
|
|
|
| |
|
|
|
|
|
| 60 seconds after the call |
|
|
|
|
|
|
| ends. |
|
|
|
|
|
|
| 3 |
|
|
|
|
|
|
| 90 seconds after the call |
|
|
|
|
|
|
| ends. |
|
|
|
|
|
|
|
|
|
Outdoor | 24 | 0 |
| No outdoor | 1 | Outdoor temperature |
|
temperature |
|
|
| temperature displays |
| displays. Requires a |
|
display (select |
|
|
|
|
| TAYSENS100A Outdoor |
|
models) |
|
|
|
|
| Sensor. |
|
|
|
|
|
|
|
|
|
28 | 0 |
| No fan delay | 1 or 2 |
| ||
Enable |
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
Minimum | 30 | 4 |
| Heating and cooling | 3 thru 10 | Heating and cooling |
|
Deadband |
|
|
| setpoints can be set |
| setpoints can be set no |
|
Between |
|
|
| no closer than 4°F |
| closer than the chosen |
|
Heating and |
|
|
| (2°C) |
| value: |
|
Cooling in Auto |
|
|
|
|
|
| |
Changeover |
|
|
|
|
|
| |
Mode |
|
|
|
|
|
| |
|
|
|
|
|
|
| |
|
|
|
|
|
|
| |
|
|
|
|
|
|
| |
|
|
|
|
|
|
| |
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
Minimum On | 32 | 5 |
| 0 thru 15 | Minimum number of minutes |
| |
Time (Heat) |
|
|
| time for compressor |
| (0 thru 15) the compressor |
|
|
|
|
|
|
| will be on during call for |
|
|
|
|
|
|
| heat |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| (continued) |