Transition Networks |
Connecting power to the Industrial Switch, continued
Barrel connector A barrel connector interface cable is included with the Industrial Switch and can be used to
interface cable convert the barrel connector output of an external AC/DC power supply over to a wire interface that can then be inserted into the terminal block following the instructions and figure 9, both located on page 13 of this manual.
Note: An external AC/DC power supply is not included with the Industrial Switch. Transition Networks offers an accessory power supply that can be purchased separately, if required. Please see optional accessories in the general information section of this manual for ordering information.
CAUTION
The operating temperature of the Industrial Switch, when used in conjunction with an AC/DC power supply will be limited to the lesser operating temperature range of either device.
For example:
Operating temp for combination is
Step | Action |
1. | Locate the barrel interface cable included in the Industrial Switch packaging. |
2. | Strip the power wires as required. |
3. | Insert one stripped power wire into the terminal block plug, Observe polarity. See |
| Figure 9 on page 13. |
4. | Secure the wire using a flathead screwdriver by tightening the contact screw. |
| See Figure 9 on page 13. |
5. | Repeat Steps 3 and 4 until all wires are installed and secured. |
6. | Locate an external AC/DC power supply with barrel connector interface and |
| make sure the power supply is not plugged into any power source. |
7. | Insert barrel connector into the receptacle on the interface cable. See Figure 11. |
External AC/DC power supply with barrel connector
Barrel Connector
Interface Cable
Figure 11: Barrel Connector Interface Cable with external power supply
Step | Action |
8.Plug external AC/DC power supply into an external power source.
9.Turn ON or plug in the external power supply and the PWR LED should turn ON along with PWR 1 LED and/or PWR 2 LED, depending on whether one or both power supplies are connected and turned ON.
| 15 |