Light Emitting Diodes (LEDs)
LEDs | The Industrial Switch has LED indicators located on its front panel. The LEDs present | ||
| glance network status, and provide | ||
| LEDs and a chart that explains the function of each. |
| |
|
|
|
|
|
| LED | Description |
|
| PWR | Green = input power present on either |
|
|
| of the power inputs |
|
|
|
|
|
| PWR1 | Green = input power present on PWR1 |
|
|
| input |
|
|
|
|
|
| PWR2 | Green = input power present on PWR2 |
|
|
| input |
|
|
|
|
|
| LNK/ACT | Green = copper link |
|
| (UTP port 5) | Green (blinking) = UTP port is receiving |
|
| link pulses or data from a | |
|
|
| |
|
|
| |
|
|
| Off = No device attached |
|
|
|
|
|
| FDX/COL | Orange = Full duplex |
|
| (UTP port 5) | Off = Half duplex or no device attached |
|
|
| Orange (blinking) = Collisions occurring |
|
|
|
|
|
| LNK/ACT | Green = UTP link |
|
| (UTP ports | Green (blinking) = UTP port is receiving |
|
| link pulses or data from a | |
|
|
| |
|
|
| |
|
|
| Off = No device attached |
|
|
|
|
|
| FDX | Orange = Full duplex |
|
| (UTP ports | Off = Half duplex or no device attached |
|
|
| Orange (blinking) = Collisions occurring |
|
|
|
|
Figure 14: LEDs and Description Chart