Transition Networks SISTF10xx-141-LR(T) installation manual Connecting fiber cables

Models: SISTF10xx-141-LR(T)

1 42
Download 42 pages 46.26 Kb
Page 24
Image 24
Connecting fiber cables

Transition Networks

SISTF10xx-141-LR(T) Industrial Unmanaged Switch

Connecting fiber cables

Fiber cable

When connecting fiber cables to the 100BASE-FX port on the Industrial Switch, make sure the

installation

correct type is used: ST or SC.

 

To install the fiber cables, do the following:

 

 

 

 

Step

Action

 

1.

Remove and keep the fiber-port protective dust cover(s).

Note: When not connected to a fiber cable, keep the protective cover(s) on the optical ports to protect the optics and keep dust and debris from entering the optical interface.

2.

Check that the fiber connectors on the fiber-optic cabling are clean. If necessary, clean the fiber connectors using locally accepted cleaning procedures.

Note: Dirty fiber connectors on fiber optic cables will impair light transmission quality through the cable and lead to degraded performance on the port.

3.

Connect the fiber cable as shown in Figure 12.

Figure 12: Fiber Cable Connections

4.

Check the corresponding fiber port LED on the Industrial Switch to verify the connection—LNK/ACT LED should be lit.

Manual background Warning

Visible and invisible laser radiation when open: DO NOT stare into the beam, or directly view the beam with optical instruments. Failure to observe this warning could result in an eye injury.

Use of controls, adjustments or the performance of procedures other than those specified herein may result in hazardous radiation exposure.

16

24-Hour Technical Support: 1-800-260-1312 International: 00-1-952-941-7600

Page 24
Image 24
Transition Networks SISTF10xx-141-LR(T) installation manual Connecting fiber cables