Tripp Lite APSX2012SW Battery Voltage LED, Voltage Setting Switch, Search Mode Setting Switch

Models: APSX1012SW

1 48
Download 48 pages 27.3 Kb
Page 5
Image 5
1.2.7 Battery Voltage (LED 5-8)

1. Overview and Features

1.2.7 Battery Voltage (LED 5-8)

LED 5-8 indicate the battery capacity as detailed in the following table:

Battery Voltage

LED 5

LED 6

LED 7

LED 8

25%

On

50%

On

On

75%

On

On

On

 

 

 

 

 

100%

On

On

On

On

 

 

 

 

 

1.2.8 Voltage Setting (Switch 1-3)*

Switch

ON

OFF

 

 

 

DC-to-AC Transfer Delay (Switch 1)

30 sec (Default)

5 sec

Low Battery Alarm (Switch 2)

11.2V

10.9V (Default)

AC Transfer Voltage (Switch 3)

190V

170V (Default)

* Notes:

1.Switches are located farthest from the battery temperature port. See diagram on page 3.

2.The switches must be set before the system is turned on.

3.Switch 2 sets the low battery voltage alarm level (at higher voltage setting, alarm will sound sooner).

4.Switch 3 sets the low-level AC-to-DC voltage point. If the AC input voltage decreases to below the setpoint, the inverter will automatically switch to DC MODE. See the following table for details.

Nominal Voltage

Low Voltage Transfer Point (AC-to-DC)

Return Voltage Point (DC-to-AC)

230V

On

190

200

 

 

 

Off

170

180

 

 

 

 

 

1.2.9 Search Mode Setting (Switch 4)

Search Mode activates when the unit is operating in inverter mode (battery power) to prevent unnecessary battery discharge when electrical power is not required. If the inverter is supporting loads that must constantly be powered, turn off switch 4 to disable Search Mode.

Switch 4

 

 

Search Mode

Function

 

 

 

 

 

 

 

ON

 

 

Enable

Inverter turns on only if load is >100W

OFF (Default)

 

 

Disable

Inverter always on if AC power is absent

1.2.10 Floating Voltage/Battery Type (Switch 5)

 

 

 

 

 

 

 

 

 

Switch 5

 

Floating Voltage

Acceptance Voltage

 

Battery Type

ON (Default)

 

13.8V

14.5V

 

Absorbed Glass Mat (AGM)

OFF

 

13.2V

13.8V

 

Wet-Cell

 

 

 

 

 

 

 

Note: The unit will charge the battery to acceptance voltage, continue for 1 to 12 hours, then drop to floating voltage.

5

201110117 93-3054.indb 5

11/9/2011 10:57:55 AM

Page 5
Image 5
Tripp Lite APSX2012SW Battery Voltage LED, Voltage Setting Switch, Search Mode Setting Switch, Overview and Features