Important Safety Instructions continued
Battery Module Warnings
•Do not allow objects to contact the Battery Module’s two DC input terminals. Do not short or bridge these terminals together. Serious personal injury or property damage could result.
•It is normal for sparks to occur when connecting the Battery Module to the Power Supply Module.
•Due to the possibility of dangerous arcing, do not unplug the Battery Module from the Power Supply Module while the Power Supply Module is operating from battery power (whenever the cart is mobile and the Power Supply Module is not plugged into a live utility wall outlet).
•Your Battery Module does not require routine maintenance. Do not open your Battery Module for any reason. There are no
•Tripp Lite offers additional replacement Battery Modules (model #: BP12V82). Contact Tripp Lite for details.
•The Battery Module’s internal batteries are recyclable. Refer to local codes for disposal requirements, or in the USA only call
•If connecting a replacement Battery Module to the Power Supply Module, the Battery Module must have the same voltage as the Power Supply Module. Use only Tripp Lite Battery Modules
(model #: BP12V82) with the Power Supply Module.
Labeling Symbols
AC Voltage: V~ | Neutral Fusing: |
| |
DC Voltage: V | Electric Shock Hazard: |
Mounting
WARNING!
Mount the Power Supply Module and Battery Module BEFORE connection.
The mounting brackets are only designed to support a Tripp Lite Power Supply Module and a single Battery Module. Do not mount or place any other devices on the mounting brackets. The mounting brackets will not support the additional weight and may fail.
Failure to follow these warnings may lead to product damage and/or risk of personal bodily harm.
The included mounting materials are designed to adapt the Mobile Power Retrofit Kit to fit most standard mobile medical cart configurations. See diagrams on the following pages to locate the mounting procedure that matches your specific cart configuration. The mounting procedures include:
•Mounting on a Center Pole
•Mounting on a Bottom Shelf (Replacing Existing Shelf)
•Mounting on a Bottom Shelf (Using Existing Shelf)
The user must determine the fitness of the mounting materials, hardware and procedures before mounting. If the materials, hardware or procedures are not suitable for your application, contact Tripp Lite for assistance.
3