SETUP
The following information lists Dipswitch setting and string commands.
Dipswitch 1 & 2. Baud Rate setting
******** Only read on power up or reset ********
1 | 2 | Baud Rate | |
0 | 0 | 9600 | default |
0 | 1 | 300 |
|
1 | 0 | 1200 |
|
1 | 1 | 4800 |
|
Dipswitch 3 OFF, (Dipswitch 4 OFF) = Computer mode. Only read on power up or reset
NOTE: This would be the mode used for Windows Socket and Virtual COM port applications.
RELAY COMMANDS *0OR1L = Latch relay 1 *0OR1F = Unlatch relay 1 *0OR1P = Pulse relay 1
*0OR2L = Latch relay 2 *0OR2F = Unlatch relay 2 *0OR2P = Pulse relay 2
INPUT STRINGS
*011 = Input 1 High
*010 = Input 1 Low
*021 = Input 2 High
*020 = Input 2 Low
PRODUCT & VERSION REQUEST
*uU =
Dipswitch 3 ON, (Dipswitch 4 OFF) = Pair mode, inputs from one
NOTE: This would be the mode used with Serial Bridge/Tunneling, with or with- out email triggering.
To program the
WEBSITE:
Visit our web site for product updates and additional information
SETUP
4