Contents
3-Phase 50kVA & Above
Owners Manual
SmartOnline
Intelligent True On-Line UPS Systems
Battery Warnings
UPS Location Warnings
UPS Connection Warnings
Equipment Connection Warnings
Important Safety Warnings continued
Breakers, Switches & Fuses
Buttons
LCD Display
LED Panel
Installation Checklist
Communication Interface
Floor Weight Loading Table
Connection Checklist Recommended Cable Sizes Terminal Wiring Diagrams
Parallel Wiring Diagrams
Connection Checklist
Terminal Wiring Diagrams
Electrical Connection continued
Parallel Wiring Diagrams
Shutdown Procedure
Start-Up Procedure
Manual Maintenance Bypass Procedure
Start-Up Procedure
Single UPS Operation continued
Shutdown Procedure
Manual Maintenance Bypass Procedure
This procedure removes power from and shuts down the UPS
Start-Up Procedure Shutdown Procedure
Manual Maintenance Bypass Procedure Operational Modes
Operational Modes
Normal Mode
Multiple UPS Operation Parallel continued
Multiple UPS Operation Parallel continued
Start-Up Procedure
Multiple UPS Operation Parallel continued
Shutdown Procedure
Manual Maintenance Bypass Procedure
Step 1. For each UPS power module in the parallel configuration which will be placed on bypass, simultaneously press the “OFF” and “” Buttons and hold for 3 seconds. The power modules inverter will turn off its LCD Screen will display “Output Close” and support of the equipment load will be transferred and shared equally among the other UPS power modules in the parallel configuration that have not yet been placed on bypass. As each consecutive power modules inverter is turned off, however, a point will be reached where the power modules which have not yet been placed on bypass will not be able to share the combined load. At this point, the remaining power modules will automatically shut down their inverters, transfer the load to reserve power and display “Bypass Mode” on their LCD Screens
Measure Page Parameter Setting System Control Event Log
Main Menu
Other Information “Measure Page” Sub-Menu
“Parameter Setting” Sub-Menu
LCD Display Navigation continued
A B C D
E F G H
LCD Display Navigation continued
“System Control” Sub-Menu
“Event Log” Sub-Menu
A B C D
“Other Information” Sub-Menu
UPS Status Code
Dry-Contacts Remote Emergency Power Off EPO
Ethernet Power
Communications continued
GENERATOR CONTACT
RS-232 Port/Ethernet Port/SNMP Card Slot
RS-485 Port
TERMINAL RESISTOR FOR RS-485
RS-485 Port
UPS Parallel Communication Port