ELECTRICAL INSTRUCTIONS

True Food Service Equipment, Inc.

INSTALLATION / OPERATION INSTRUCTIONS

ELECTRICAL INSTRUCTIONS

Step 4

A.Before your new unit is connected to a power supply, check the incoming voltage with a voltmeter. If anything less than 100% of the rated voltage for operation is noted, correct immediately.

B.All units are equipped with a 9 ft. (3m) service cord, and must be powered at proper operating voltage at all times. Refer to cabinet data plate for this voltage.

True requires that a sole use circuit be dedicated for the unit. Failure to do so voids warranty.

WARNING

Compressor warranties are void if compressor burns out due to low voltage.

WARNING

Power supply cord ground should not be removed!

NOTE

To reference wiring diagram - Remove front louvered grill, wiring diagram is positioned on the inside cabinet wall.

Curved Glass Deli Cases

Deli cases are equipped with a service receptacle

(found on the upper left cabinet backside), no electrical load greater that 4.0 amps should be connected to it. If the electrical load is greater that 4.0 amps, it should be wired separately or a larger lead cord should be wired in place of the provided lead cord. Use a cord with a 20 amp male plug (NEMA-5-20P).

STARTUP

Step 5

A.The compressor is ready to operate. Plug in the unit.

B.Check the temperature control setting in the upper left of the cabinet backside. The setting should be at #5 to maintain an approximate 38˚F (3.3˚C). Set defrost time clock to the correct time of day.

NOTE

Excessive tampering with the control is not recommended as this can lead to service difficulties. Should it ever become necessary to order a replacement temperature control, be sure it is ordered from a dealer or recommended parts stocking service company.

C.Verify that the cabinet lights are working. Deli cases are shipped with light switches in the “on” position. The toggle switch is located upper left corner at the rear.

NOTE

If the deli case is disconnected or shut off, wait five minutes before starting again.

RECOMMENDATION

Before loading product we recommend you run your True unit empty for two to three days. This allows you to be sure electrical wiring and installation are correct and no shipping damage has occurred. Remember, our factory warranty does not cover product loss!

REPLACEMENT PARTS

TRUE maintains a record of the cabinet serial number for your unit. If at any time during the life of your display case, a part is needed, you may obtain this part by furnishing the model number and serial number to the company from whom you purchased the cabinet. Call Toll-Free: (800)-424-TRUE (Direct to Parts Department). (800)-325-6152 (U.S.A. & Canada only) or call: (636)-240-2400.

Serial Number Power supply cord ground should not be removed!