True Manufacturing Company TFP-32-12M-D-2 installation manual Sequence Of Operation, Startup

Models: TFP-32-12M-D-2

1 16
Download 16 pages 57.35 Kb
Page 11
Image 11
SEQUENCE OF OPERATION

True Food Service Equipment, Inc.

INSTALLATION / OPERATION INSTRUCTIONS

SEQUENCE OF OPERATION

Temperature Control Sequence of Operation

When the cabinet is plugged the unit will start up in a defrost cycle. The evaporator fan is hard-wired and will continue to run during this time. The cooler will stay in defrost for a minimum of 4 minutes or until the coil temperature reaches at least 41˚F. The maximum time the cooler will be in defrost is 40 minutes. At the end of the defrost cycle, there will be a 2 minute delay to allow any water to drip off of the evaporator coil. After this time, the compressors will come on and the cooler should start to cool down. The compressors will run until the temperature control is satisfied. Every 4 hours of compressor run time, the cooler will go into defrost and remain in defrost until the coil temperature reaches 41˚F.

NOTE:

When the unit is first plugged in it will take at least 6 minutes

before the compressor starts.

STARTUP

A.The compressor is ready to operate. Plug in the cooler.

B.Temperature control set at No. 4 position gives refrigerators an approximate temperature of 35°F. Allow unit to function several hours, completely cooling cabinet before changing the control setting.

C.Excessive tampering with the control could lead to service difficulties. Should it ever become necessary to replace temperature control, be sure it is ordered from your TRUE dealer or recommended service agent.

D.Good air flow in your TRUE unit is critical. Be careful to load product so that it neither presses against the back wall, nor comes within four inches of the evaporator housing. Refrigerated air off the coil must circulate down the back wall.

NOTE

If the cooler is disconnected or shut off, wait five minutes before starting again.

RECOMMENDATION

Before loading product we recommend you run your TRUE unit empty for two to three days. This allows you to be sure electrical wiring and installation are correct and no shipping damage

has occurred. Remember, our factory warranty does not cover product loss!

REPLACEMENT PARTS

TRUE maintains a record of the cabinet serial number for your cooler. If at any time during the life of your cooler, a part is needed, you may obtain this part by furnishing the model number and serial number to the company from whom you purchased the cooler. Call Toll-Free: (800)-424-TRUE (Direct to Parts Department). (800)-325-6152 (U.S.A. & Canada only) or call: (636)-240-2400.

TEMPERATURE CONTROL LOCATION

The temperature control is located are the back of the unit. (See image 1).

 