SEQUENCE OF OPERATION
Temperature Control Sequence of Operation
When the cabinet is plugged the unit will start up in a defrost cycle. The evaporator fan is
NOTE:
When the unit is first plugged in it will take at least 6 minutes
before the compressor starts.
STARTUP
A.The compressor is ready to operate. Plug in the cooler.
B.Temperature control set at No. 4 position gives refrigerators an approximate temperature of 35°F. Allow unit to function several hours, completely cooling cabinet before changing the control setting.
C.Excessive tampering with the control could lead to service difficulties. Should it ever become necessary to replace temperature control, be sure it is ordered from your TRUE dealer or recommended service agent.
D.Good air flow in your TRUE unit is critical. Be careful to load product so that it neither presses against the back wall, nor comes within four inches of the evaporator housing. Refrigerated air off the coil must circulate down the back wall.
NOTE
If the cooler is disconnected or shut off, wait five minutes before starting again.
RECOMMENDATION
Before loading product we recommend you run your TRUE unit empty for two to three days. This allows you to be sure electrical wiring and installation are correct and no shipping damage
has occurred. Remember, our factory warranty does not cover product loss!
REPLACEMENT PARTS
TRUE maintains a record of the cabinet serial number for your cooler. If at any time during the life of your cooler, a part is needed, you may obtain this part by furnishing the model number and serial number to the company from whom you purchased the cooler. Call
TEMPERATURE CONTROL LOCATION
The temperature control is located are the back of the unit. (See image 1).