g. If D-sensor's temperature does not reach 47˚F(8˚C) in 40 minutes,

ELECTRONIC CONTROLLER INSTRUCTION

No

Control Function

Control Objects

Contents

Remark

 

 

 

 

 

5

Defrost

Heater

f. If Defrost Heater's on time exceeds 40 minutes for any reason, a

 

 

Function

Compressor

back-up defrost termination switch is also provided.

 

 

 

Evap-Fan Motor

g. If D-sensor's temperature does not reach 47˚F(8˚C) in 40 minutes,

 

 

 

Con-Fan Motor

error code will be recorded on a MICOM.

 

 

 

 

TEMPERATURE

 

Turbo air

Long Beach, CA

T.F. FAN DOOR

LAMP

TURBO FREEZE

POWER

C. Pause step

a. Time = 3 min.

b. 88 LED displays 'dF'

D. Fan delay step

 

 

 

 

a. Max. Time = 5 min

 

 

 

 

b. Only Comp. is On.

 

 

 

 

c. If D-sensor temperature goes down under 14˚F in 5 minutes,

 

 

 

 

Evap.-Fan Motor turns on immediately.

6

Manual

Compressor

1.

Press the Turbo Freeze button 5 seconds, While pressing both

 

Defrost

Evap-Fan Motor

 

up/down button at the same time.

 

 

Con-Fan Motor

2.

Manual defrost mode.

 

 

Heater

 

a) The pre-cool step is omitted.

 

 

 

 

b) It starts from heater defrost step.

 

 

 

 

c) The next procedure is the same as that of the defrost mode.

7

Comp

Compressor

1.

Compressor will not start for 3 minutes after compressor is off, even

 

Restart

Con-Fan Motor

 

though the F-sensor is at on point.

 

Prevent

 

 

 

8

Power

Compressor

1.

Compressor will not strat for 3 minutes after power failure.

 

Failure

Evap-Fan Motor

2.

Evap.-Fan Motor is on.

 

Back-Up

Con-Fan Motor

 

 

 

Function

 

 

 

9

Door opening

Buzzer

1.

If door is opened, light on display board for fan turns off and door

 

Alarm function

LED

 

open indicating lamp turns on.

 

 

 

2.

If door is opened more than 30 seconds, display will beep 3 times.

 

 

 

3.

If door is opened more than 60 seconds, display will beep 5 times.

 

 

 

4.

If door is opened more than 5 minutes, display will beep

 

 

 

 

continuously.

10

Buzzer

Buzzer

1.

Beep sound rings 1 time after initial power on.

 

Function

 

2.

Beep sound rings whenever each button is pressed.

 

 

 

3.

Beep sound rings if door is opened a certain time period. (See door

 

 

 

 

opening alarm function)

11

Error

LED

1.

Press up button 5 times while pressing both down button and Turbo

 

Display

 

 

Freeze button at same.

 

 

 

 

Above procedure switches normal display to error display mode.

 

 

 

2.

If there was no error occurred, there will be no change on the 88

 

 

 

 

LED.

 

 

 

 

If there was error occurred, 88 LED will display the error code.

 

 

 

3.

Next error code will be displayed by pressing down button.

 

 

 

4.

10 seconds after the last button pressed, error display mode will be

 

 

 

 

switched to normal display mode.

103

Page 106
Image 106