28 MAINTENANCE AND TROUBLESHOOTING

I S S U E

POSSIBLE CAUSE(S)

RESOLUTION

 

 

 

F1: Blower Running

† Oven power interrupted.

† Verify wall circuit breaker is on.

Status Bad

 

Reset breaker and then power the

 

 

oven back on.

 

 

† Place the oven into Off State for two

 

 

(2) minutes, disconnect the plug for

 

 

minimum of two (2) minutes, re-plug

 

 

in the oven and and press the OVEN

 

 

ON soft key.

 

 

 

F2: Cook

† Oven power interrupted.

† Verify wall circuit breaker is on.

Temperature Low

 

Reset breaker and then power oven

 

 

back on.

 

† Air nozzles on the top of the

† Open oven door and verify the air

 

cook cavity are clogged.

nozzles on the top of the cook cavity

 

 

are clean and not clogged.

 

† Oven door is out of alignment.

† Open and close the door several times

 

 

and verify oven door is closed. Reset

 

 

high-limit located in the bottom left

 

 

corner of the oven rear wall.

 

† Defective heater.

† Call Customer Service.*

 

† Blower motor not running.

† Perform self-test (page 26) and call

 

 

Customer Service.*

 

† Oven not fully warmed-up.

† Repeat warm-up and allow oven to

 

 

idle for five (5) minutes.

 

 

 

F3: Magnetron

† Microwave circuit defective.

† Perform self-test (page 26) and call

Current Low

 

Customer Service.*

 

 

 

F4: Door Monitor

† Oven door switches are out of

† Perform self-test (page 26) and call

Defective

order.

Customer Service.*

 

 

 

F5: Magnetron Over

† Blockage of cool air into

† Check for paper towels or anything

Temperature

the oven.

that may be obstructing cool air into

 

 

the oven.

 

† Rear cooling fan exhaust

† Check rear fan to see if it is free of

 

guard is clogged.

debris. Clean as required.

 

 

 

Page 38
Image 38
Turbo Chef Technologies Tornado owner manual F1 Blower Running