Removal of the HF compression driver and LF driver – two-way cabinets

The perforated steel loudspeaker grille is held in place by six M5 button head screws, three on each side of the cabinet (NuQ-8 illustrated here). Remove these grille retaining screws and set the grille aside for later re-assembly.

Undo the screws holding the low frequency driver in place and carefully lift it out and away from the cabinet. Make a note of the driver polarity for later reconnection. Disconnect the cables from the drive unit and completely remove the driver from the cabinet being careful not to damage the cone or suspension. Do not place the driver near to any equipment or media that may be adversely affected by strong magnetism, e.g. CRT monitors or magnetic tape of any kind.

Remove the horn/driver assembly by unscrewing the four screws holding the flange in place. Lift it out and away from the cabinet. The high frequency driver can now be disassembled from the HF horn.

To reinstate the driver(s) simply reverse the above procedure, making sure you observe the correct polarity when reconnecting the cables back into the terminals of the drive units.