If ice maker is not used regularly, the ice bucket should be emptied peri- odically to ensure fresh cubes.
It is normal for cubes to appear cloudy. This is caused by air being trapped in the water due to fast freezing. It has nothing to do with the health, taste or chemical
To provide for higher ice rate (production of more cubes), adjust the temperature control to a warmer setting. If hollow cubes result, adjust temperature somewhat colder. For less cube production, adjust to a colder setting.
The ice bucket must be fully inserted in the freezer section.
The ice bin door must be fully closed.
For frost free models: Do not place any objects over air inlet or outlet in freezer section.
For frost free models: Light frosting may occur in high humidity condi- tions or if the ice bucket is not pushed in completely.
ADJUSTING THE TEMPERATURE
CONTROL
Models
Series 15, 29 and 75: Adjust control setting by turning the numbered dial, recessed behind the front grill, by the
6 |
| 5 | 4 |
|
7 | O |
| R | 3 |
| LD |
| ||
8 | C | E |
| |
|
| 2 | ||
|
|
| ||
9 |
|
|
| 1 |
|
|
|
|
UL012A
Figure 34
Model SP18 temperature control has been preset at the factory for optimum ice production. Do not attempt to make adjustments.