4.For recessed installations, allow extra water supply line length to provide slack for easy removal from the recessed area (see Figure 7). This will also safeguard against kinking the line.

NOTE

If you are not intending to use the ice maker and do not connect the water supply (or turn the supply valve off), it is imperative to raise the bin arm of the ice maker (see Figure 8).

UL002A

Figure 8

UL100

Figure 7

NOTE

After completing the installation, turn on the water and recheck water connection for leaks. Apply additional tight- ening if needed. Do not use thread sealing compound or tape.

NOTE

On Models BI-95 and BI-98, route the water supply line through the unit in such a way as to prevent the line from coming in contact with any internal components other than the solenoid valve (see Figure 6). Normal operation creates some vibration. A water supply line contacting an internal component or cabinet wall may cause excessive noise dur- ing operation or damage to the line.

5.Install the grill. See GRILL INSTALLATION.

6.Plug in the power cord.

7.Gently push the unit into position. If desired the unit may be recessed into cabinet or wall. Model PBCM-98 is free standing and cannot be permanently recessed, but can be pushed under a counter.