6 Cleaning and Maintenance

MARINE SERIES

6 Cleaning and Maintenance

Proper cleaning and maintenance of your U-Line product will ensure efficiency, top performance and long life. The maintenance intervals listed are based on normal conditions. You may want to shorten the intervals if you have pets or other special considerations.

Interior Cleaning (As Required)

Turn unit off. Clean the interior and all removed components using a mild non-abrasive detergent and warm water solution applied with a soft sponge or non-abrasive cloth. Rinse the interior using a soft sponge and clean water.

Do not use any solvent-based or abrasive cleaners. These types of cleaners may transmit taste to the interior products and damage or discolor the interior.

Defrosting

Manual Defrost Models - Every Two Months (Minimum)

Interior Cleaning (As Required)WARNING

DO NOT use any type of electrical heating device, ice pick, knife or other sharp instrument to defrost; this could damage the inner lining or refrigeration system and void the warranty.

Ice

Bucket

ULIN_1045_A

Figure 7

To defrost:

1.Turn unit off.

2.Remove ice bucket and discard ice.

3.Place a towel or other absorbent material on bottom of unit.

4.If you would like, place warm water inside ice bucket. Then place ice bucket back into unit and close door.

5.After approximately one hour, remove ice bucket and discard water.

6.Allow the frost to completely melt naturally. Clean the interior and ice bucket using a mild non-abrasive detergent and warm water solution applied with a soft sponge or non-abrasive cloth.

DefrostingCAUTION

DO NOT use any solvent-based or abrasive cleaners. They will discolor or damage the interior.

7.Dampen a soft sponge or non-abrasive cloth in clean water and wipe down the cabinet interior and ice bucket to remove any detergent residue. Rinse the sponge or cloth in clean water and repeat as necessary until the cabinet and ice bucket are clean.

IMPORTANT

DO NOT place ice bucket in dishwasher. Dishwasher will warp/discolor ice bucket and render it useless.

Condenser Cleaning

Interval - Every Three Months

To maintain operational efficiency, keep the front grille free of dust and lint, and clean the condenser every three months. Depending on environmental conditions, more or less frequent cleaning may be necessary.

Manual Defrost Models - Every Two Months (Minimum)WARNING

Disconnect electric power to the unit before cleaning the condenser.

To remove and replace the grille for access to the condenser fins, follow this procedure:

Model ULN-SS1095FD

 