GAS CONNECTION

The gas inlet connection is 3/8" NPT. Connect gas line to gas inlet on rear of control valve (Note: we recommend a 3/8" Flexible Gas line. Then connect a Manual Shutoff Valve and gas supply line as shown in FIGURES 4 & 5.

Test all gas joints from the gas meter to the heater for leaks using soap and water solution after completing connection. DO NOT USE AN OPEN FLAME.

FIGURE 5. Option #2 for gas connection

GAS PRESSURE CHECK

The heater regulator controls the burner pressure which should be checked at the pressure test point located on the right side of the main control and is accessible from the side of the gas log assembly (see FIGURE 6).

The pressure should be checked with the heater burning and the control set to high (HI).

The pressure regulator is preset and locked to avoid tampering. If the pressure is not as specified in Product Specifications (Page 5), contact your dealer and replace the regulator.

FIGURE 6. Pressure Test Point Location