TROUBLESHOOTING, CONTINUED...

OBSERVED PROBLEM

POSSIBLE CAUSE

 

 

REMEDY

ODS/Pilot lights, but flame goes out

• Thermocouple connection loose at

• Hand tighten until snug, then

When control knob is released.

control valve.

tighten 1/4

turn

more.

(continued from page 25)

• Pilot flame not touching thermocouple,

Contact

local

gas company.

 

which allows thermocouple to cool,

 

 

 

 

 

 

causing pilot flame to go out. This

 

 

 

 

 

 

problem could be caused by either

 

 

 

 

 

 

low gas pressure, or a dirty or partially

 

 

 

 

 

 

clogged ODS/pilot.

 

 

 

 

 

 

• Thermocouple damaged.

Replace

thermocouple.

 

• Control valve damaged.

Replace

control valve.

 

 

 

One or both burner do not

• Burner orifice is clogged.

• Clean burner or replace burner

light after ODS/pilot is lit.

• Burner orifice diameter is too small.

orifice.

 

 

 

 

Replace

burner orifice.

 

• Inlet gas pressure is too low.

Contact

qualified service person.

 

 

 

Burner backfires during

• Manifold pressure is too low.

• Contact local gas company.

combustion.

• Burner orifice is clogged.

• Clean burner or replace burner

 

 

orifice.

 

 

 

 

 

 

Slight smoke or odor during

• Burner orifice is clogged or damaged.

• Clean burner or replace burner

initial operation.

• Burner is damaged.

orifice.

 

 

 

 

Replace

burner.

 

• Gas regulator defective.

Replace

gas

regulator.

 

 

 

Logs appear to smoke after

• Vapors from paint or curing process

• Problem will stop after a few hours

initial operation.

of logs.

of

operation.

Run the heater with

 

 

the damper open if you have one,

 

 

or open a window for the first few

 

 

hours.

 

 

 

 

 

• Log heater is intended to be

 

 

smokeless. Turn OFF heater and

 

 

call qualified

service person.

 

 

 

Heater produces a whistling

• Turning control knob to HIGH (3)

• Turn control knob to LOW (2)

noise when burner is lit.

position when burner is cold.

position and let warm up for a

 

 

minute.

 

 

 

 

• Air in gas line.

• Operate burner until air is removed

 

 

from line. Have gas line checked

 

 

by local gas company.

 

• Dirty or partially clogged burner

• Clean burner or replace burner

 

orifice.

orifice.

 

 

 

 

 

 

No gas to pilot.

LP-regulator shut down due to inlet

• Verify LP tank regulator is

 

pressure too high.

installed and set

to 11" to 13"w.c.

Replace regulator on heater.

WARNING

If the gas quality is bad, your pilot may not stay lit, the burners may produce soot and the heater may backfire when lit. If the gas quality or pressure is low, contact your local gas supplier immediately.