| SPECIFICATIONS | |||
Natural Gas |
|
|
|
|
|
|
|
|
|
Manifold Pressure Setting 4" w.c. |
|
|
|
|
|
|
| ||
Gas Inlet Pressure | Maximum |
|
|
|
|
|
| ||
| Minimum 5" w.c. |
|
|
|
|
|
| ||
|
|
|
| Gas Rate |
|
| Number | ||
|
|
|
|
| |||||
Model Number |
| Type | Max BTU/Hr |
| Min BTU/Hr |
|
| of Burners | |
|
| ||||||||
|
|
|
|
|
|
|
|
|
|
VF30IN |
|
| Manual | 30,000 |
| 16,000 |
|
| 1 |
Propane / LPG |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
Note: An external regulator is required to reduce supply pressure to a maximum of 13" w.c. |
| ||||||||
Manifold Pressure Setting 10" w.c. |
|
|
|
|
|
|
| ||
Gas Inlet Pressure | Maximum 13" w.c. |
|
|
|
|
|
| ||
| Minimum 11" w.c. |
|
|
|
|
|
| ||
|
|
|
| Gas Rate |
|
| Number | ||
|
|
|
|
|
| ||||
Model Number |
| Type | Max BTU/Hr |
| Min BTU/Hr |
|
| of Burners | |
| |||||||||
|
|
|
|
|
|
|
|
|
|
VF30IL |
|
| Manual | 30,000 |
| 16,000 |
|
| 1 |
|
|
|
|
|
|
|
|
|
|
Controls - Main control has 4 positions:
1.OFF - All gas to the gas logs is shut off at the control
2.IGN - Piezo ignitor allows ignition of the pilot without the use of matches or batteries
3.PILOT - Valve position to light / maintain a standing pilot
4.ON - Gas flow to complete system, front burner ignition
Burner Control Knob - Infinite control, rotate clockwise to minimum rate and counterclockwise for maximum rate. Adjust the control knob between Minimum and Maximum to gain the desired room temperature. The control will automatically cycle the heater on and off to maintain the desired heat in the room. There are no exacts with the adjustment, you will need to experiment with the setting to find what works best for you needs.
CONTENTS
VF30IN and VF30IL
1.Owner's manual.
2.Log box containing four (4) fiber ceramic logs, refer to installation instructions.
3.
CAUTION
CHECK THAT ALL LISTED PARTS HAVE BEEN RECEIVED
GLOVES ARE RECOMMENDED WHEN HANDLING CERAMIC FIBER LOGS TO PREVENTSKIN IRRITATIONFROMLOOSEFIBERS.LOGSAREFRAGILE, HANDLE WITH CARE.
Carefully inspect the contents for shipping damage and immediately inform your dealer if any damage is found.
5