OPERATING INSTRUCTIONS

LIGHTING INSTRUCTIONS

1.STOP! Read the safety information on the previous page.

2.Turn off all electrical power and open the access door.

3.Turn off the rear burner and set the front burner to low.

4.Push in gas control (knob 1) slightly and turn

clockwise to "OFF".

NOTE: Knob cannot be turned from "PILOT" to "OFF" unless knob is pushed in slightly. Do not force.

5.Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow "B" in the safety information on the previous page. If you don't smell gas, go on to the next step.

PILOT LOCATION

TOP VIEW OF BURNER ASSEMBLY

6.Push in the control (knob 1) all the way and

rotate counter-clockwise to "PILOT". The piezo ignitor will light the pilot as the knob passes "IGN" traveling to the "PILOT". Con tinue to hold the control (knob 1) in for about ten (10) seconds after the pilot is lit. Release knob and it should pop back up. Pilot should remain lit. If it goes out, repeat steps 4 through 6. If the control (knob 1) does not pop up when released, stop and immediately call your ser vice technician or gas supplier. If the pilot will not stay lit after several tries, turn the gas control (knob 1) to "OFF" and call your service technician or your gas supplier.

7.Turn gas control (knob1) counter-clockwise

to "ON".

8.Set the burner (knob 2) to the desired setting

rotating counter-clockwise to MAX. and

clockwise to MIN.

9.Close access door and turn on electrical power.

TURN OFF GAS TO APPLIANCE

1.Open access door.

2.Set burner to Min. by rotating knob clockwise until stop.

3.Unplug all electric power if service is to be performed.

4.Push in gas control knob slightly and turn clockwise to "OFF". Do not force.

5.Close access door.

19