Universal Electronics 975 operating instructions Wiring Diagrams, L J I K M

Models: 975

1 44
Download 44 pages 43.34 Kb
Page 10
Image 10
WIRING DIAGRAMS

WIRING DIAGRAMS

All wiring diagrams are for typical systems only. Refer to equipment manufacturers’ instructions for specific system wiring information.

MV

6

Y

G

W

E

1From heating system

2From 24 VAC transformer

3Red jumper wire (provided) See page 10 for letter identification.

1 2 3

H

O

B

RC

RH

W

RH

MV W RH RC G Y O B 6

L

J I K

M

NOTE: Ensure that RED RH/RC jumper wire (provided with thermostat) is connected between thermostat’s RH and RC terminals for proper operation with this system.

Figure 2. Typical wiring diagram for heating only, two-wire, single transformer system

8

Page 10
Image 10
Universal Electronics 975 operating instructions Wiring Diagrams, L J I K M