INSTALLING BLOWER ACCESSORY

INSTALLATION

Continued

INSTALLING BLOWER ACCESSORY

(Model FB32CA only)

You may install blower accessory GA3700 with conventional installation (below) or with built-in installation (page 11) with models FB32CA and NLFB32C only.

Conventional Installation of Blower Accessory

NOTICE: If a log set is currently installed in the firebox, disconnect logsetfromgassupplyandremove from firebox. Contact a qualified service person to do this.

1.Remove the firebox bottom:

a.Remove the 4 screws that secure the bottom of the firebox (see Figure 8).

b.Carefully raise and remove the firebox bottom from the firebox.

Manual background WARNING: If there is a duplex electrical outlet installed in the right side of the bottom of the fireplace base area, be sure that theelectricalpowertotheoutletis turned off before proceeding with blower installation. Failure to do this may result in serious injury.

2.Place the blower against lower rear wall of firebox wrapper with the exhaust port directed upward. Align the holes in top mounting tabs of blower with holes in wall of wrapper (see Figure 9). Using 2 screws provided, mount blower and tighten screws securely.

3.Be certain that all wire terminals are securely at- tached to terminals on blower motor and that the screw retaining the green ground wire is tight.

4.Locate the plastic hole plug installed in the 3/8" diameter opening in the lower right side of the firebox front panel (see Figure 9). Remove the plastic plug and discard.

5.Place speed control against inner wall of front panel, pushing the plastic control shaft for- ward through the opening (see Figure 10).

6.While supporting speed control, secure control shaft with lock nut by pushing and turning lock nut with pliers clockwise until it is tight against front panel. Place control knob pro- vided on shaft (see Figure 10).

Lower Rear Wall

of Firebox

Wrapper

Blower

Screws

Floor

 

Exhaust

Supports

 

Port

 

 

Plastic

 

Hole Plug

 

Top

 

Mounting

 

Tab

Figure 9 - Mounting Blower to Firebox

Speed Control

Control Shaft

Screws

Figure 8 - Removing Screws from

Firebox Bottom

Lock Nut

Control Knob

Figure 10 - Attaching Speed Control