![PRODUCT](/images/new-backgrounds/45865/458659x1.webp)
PRODUCT |
|
| PRODUCT FEATURES | ||
SPECIFICATIONS | OPERATION | ||||
| Continued |
| |||
|
| This firebox is designed for use with approved | |||
|
|
| |||
| Standoffs (Models FB32NCA | ANSI Z21.1.2 decorative type unvented room | |||
| heaters. (Physical size limitations apply. Refer to | ||||
| and NLFB32NC only) | ||||
| minimum firebox requirements supplied with log | ||||
23/4" |
| ||||
| heater.) It requires no outside venting or chimney | ||||
|
|
| |||
11/2" |
|
| making installation easy and inexpensive. When | ||
|
|
| used without the blower (models FB32CA and | ||
6" |
|
| NLFB32C only), the firebox requires no electricity | ||
|
|
| making it ideal for emergency backup heat. | ||
|
|
| BLOWER ACCESSORY | ||
3311/16" |
|
| The FB32CA and NLFB32C firebox will accept | ||
|
| the GA3700 accessory. The variable blower allows | |||
323/16" |
|
| |||
|
| you to select the fan speed you desire. The blower | |||
|
|
| |||
|
|
| circulates heated air from the firebox into the room. | ||
| 121/2" |
| Use of blower is optional. | ||
| 93/4" |
|
|
| |
|
| 45/8" |
| LOCATING FIREBOX | |
|
|
| Plan where you will install the firebox. This will | ||
|
| 21/2 | save time and money later when you install the fire- | ||
|
|
| box. Before installation, consider the following: | ||
Electrical | Electrical |
| 1. | Where the firebox will be located. Allow for | |
Access Hole | Access Hole | Gas Line |
| wall and ceiling clearances (see Installation | |
| Clearances, page 9). | ||||
| with Bushing | Access |
| ||
| 2. | Everything needed to complete installation. | |||
Figure 2 - Firebox Side View | |||||
|
| ||||
|
|
| 3. | These models CANNOT be installed in a | |
| 221/2" |
|
| bedroom or bathroom. | |
|
|
| 4. | Proper air for combustion and ventilation (see | |
|
|
|
| page 6). |
| 1 | 1611/16" |
|
|
|
|
|
|
|
|
|
|
| 131/4"* 141/4"* | ||||||||||||||
19 |
| /4" |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 315/8" |
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 343/8" |
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
| 355/8" |
|
|
|
|
|
|
|
|
|
|
|
| ||
*Note: | 14 | 1 | /4" is total firebox cavity depth | |||||||||||||||||||||||||
including brick liner. 13 | 1 | /4" is depth of flat | ||||||||||||||||||||||||||
floor including brick liner. | ||||||||||||||||||||||||||||
|
|
|
|
|
|
| Figure 3 - | Firebox Top View |
www.desatech.com | 5 |